CHAPTER 3
Menu System
SHAPESHIFTER User Manual
25
Pan Degree
The standard pan range of a SHAPESHIFTER fixture is 0–540°. This option lets you expand the
pan range to an upper limit of 630°.
To expand the pan range, scroll from the default option of
540
to
630
and press the
button to
select.
Encoders
Encoders maintain the Pan and Tilt position of the fixture, but may need to be disabled to perform
certain test and maintenance procedures. The default setting is
On
. To disable encoders, select
the
Off
option.
Pan/Tilt Speed
This options adjusts the maximum movement speed of the pan and tilt parameters. The
Speed
1
option is the default normal movement speed.
Speed
2
,
Speed 3
, and
Speed
4
options are
progressively slower maximum movement speeds.
Mic Sensitivity
You can adjust the input level for the internal microphone by setting this option from
0% –99%
.
The Default value is
70%
.
Hibernation (Standby Mode)
This menu option determines how the fixture will react in the event of DMX data loss.
Turn Hibernation off to keep the shutter open until shutdown by selecting
Off
.
Scroll to any value from
01M – 99M
to set the number of minutes after data loss before closing
the shutter. The default setting is
15M
.
Service Setting
Two options for service setting allow you to set a
Service PIN
or a
RDM PID
code.
To change the Service PIN:
1. Navigate to and select the
Set
menu as shown on
page 24
.
2. Using the
buttons, scroll to
Status
and press the
button to select.
3. Using the
buttons, scroll to
Service
PIN
and press the
button to select. The
current password will be displayed. The default is
Password = 050
.
4. Using the
buttons, scroll to a 3-digit number and press the
button to select as the
new service password.
Note: A service password must be set before you can enter a six digit RDM PID
number.