High-Flying
HF-LPT100 Low Power WiFi Module User Manual
Shanghai High-Flying Electronics Technology Co., Ltd(www.hi-flying.com)
- 24 -
3.
OPERATION GUIDELINE
3.1.
Configuration via Web Accessing
When first use HF-LPT100 modules, user may need some configuration. User can connect to HF-
LPT100
module’s wireless interface with following default setting information and configure the module
through laptop.
Table 8 HF-LPT100 Web Access Default Setting
Parameters
Default Setting
SSID
HF-LPB100
IP Address
10.10.100.254
Subnet Mask
255.255.255.0
User Name
Admin
Password
Admin
3.1.1.
Open Web Management Interface
There is internal webpage and external webpage in modules. The external webpage is for web
management. The internal webpage is only for upgrading.
Step 1: Connect laptop to SSID
“HF-LPB100” of HF-LPT100 module via wireless LAN card;
Step 2: After wireless connection OK. Open Wen browser
and access “
Step 3: Then input user name and password in the page as following and click
“OK” button.
Figure 12.
Open Web Management page
The HF-LPT100 web management page support English and Chinese language. User can select
language environment at the top right corner and click “Apply” button.
The main menu include nine
pages: “System”, “Work Mode”, “STA Setting”, “AP Setting”, “Other
Setting”, “Account”, “Upgrade SW”, “Restart”, “Restore”.
(HF-LPT100 exists 1M Flash and 2M Flash
version, 1M Flash is only with internal upgrade webpage while 2M Flash is with internal and
external webpage. Please contact High-Flying to confirm physical type.)