3.2.2.
Network Connection
User can select two methods to connect HF-LPT100 module base on dedicated application.
Use HF-LPT100 STA interface.
HF-LPT100 and debug PC2 connect to a wireless AP,
another PC1 (or user device) connect to HF-LPT100 module with serial port:
Figure 23.
STA Interface Debug Connection
Use HF-LPT100 AP interface.
Debug PC2 connect to HF-LPT100 through wireless
connection, another PC1 (or user device) connect to HF-LPT100 module with serial port.
Figure 24.
AP Interface Debug Connection
3.2.3.
Default Parameter Setting
Default SSID: HF-LPB100;
Deault security mode: open,none;
User UART parameter setting:115200,8,1,None;
Default network parameter setting:TCP,Server,8899,10.10.100.254;
Module IP address: dhcp,0.0.0.0,0.0.0.0,0.0.0.0;
3.2.4.
Module Debug
PC1 open “CommTools” program, setting the same serial port parameters with HF-LPT100 module
and open serial port connection.
Figure 25.
“CommTools” Serial Debug Tools