background image

MYK2011_100 Low Power Wi-Fi Module User Manual 

Shanghai High-Flying Electronics Technology Co., Ltd(www.hi-flying.com)

 

- 7 - 

1.2.  Hardware Introduction 

 

                               

        

 

Figure 1. 

MYK2011_100 View  

1.2.1.  Pins Definition 

 

Figure 2. 

MYK2011_100 Pins Map 

Table 2    MYK2011_100 Pins Definition 

Pin 

Describtion 

Net Name 

Signal 

Type 

Comments 

1,17,32,48 

Ground 

GND 

Power 

 

Debug Pin 

SWCLK 

I, PD 

Debug functional pin, 

Summary of Contents for MYK2011_100

Page 1: ...ffective MCU Ultra Low Power for Battery Applications with Excellent Power Save Scheme Support UART SPI PWM GPIO Data Communication Interface Support Work As STA AP AP STA Mode Support Smart Link Function APP program provide Support Wireless and Remote Firmware Upgrade Function Support WPS Function Support Multi TCP Link 5 Channel Apllication Support External I PEX Antenna Option Single 3 3V Power...

Page 2: ...ription 5 1 1 1 Device Features 5 1 1 2 Device Paremeters 6 1 1 3 Key Application 6 1 2 Hardware Introduction 7 1 2 1 Pins Definition 7 1 2 2 Electrical Characteristics 9 1 2 3 Mechanical Size 11 1 2 4 External Antenna 11 2 PACKAGE INFORMATION 13 2 1 Recommended Reflow Profile 13 2 2 Device Handling Instruction Module IC SMT Preparation 13 2 3 Shipping Information 13 3 OEM INTEGRATORS INSTALLATION...

Page 3: ...ronics Technology Co Ltd www hi flying com 3 LIST OF FIGURES Figure 1 MYK2011_100 View 7 Figure 2 MYK2011_100 Pins Map 7 Figure 3 MYK2011_100 Mechanical Dimension 11 Figure 4 MYK2011_100 PCB Symbol Size 11 Figure 5 Reflow Soldering Profile 13 Figure 6 Shipping Information 14 ...

Page 4: ...High Flying Electronics Technology Co Ltd www hi flying com 4 LIST OF TABLES Table 1 MYK2011_100 Module Technical Specifications 6 Table 2 MYK2011_100 Pins Definition 7 Table 3 MYK2011_100 External Antenna Parameters 12 Table 11 Reflow Soldering Parameter 13 ...

Page 5: ...ersonal medical application and industrial control that have lower data rates and transmit or receive data on an infrequent basis TheMYK2011_100 integrates all Wi Fi functionality into a low profile 23 1x32 8x 2 7mm SMT module package that can be easily mounted on main PCB with application specific circuits Also module provides built in antenna external antenna option 1 1 1 Device Features Single ...

Page 6: ...External I PEX Connector Hardware Parameters Data Interface UART SPI PWM GPIO Operating Voltage 2 8 3 6V Operating Current Peak Continuous TX 300mA Normal WiFi ON OFF DTIM 100ms Average 12mA Peak 300mA Operating Temp 40 85 Storage Temp 45 125 Dimensions and Size 23 1mm 32 8mm 3 45 0 3 mm Software Parameters Network Type STA AP STA AP Security Mechanisms WEP WPA PSK WPA2 PSK Encryption WEP64 WEP128...

Page 7: ...ogy Co Ltd www hi flying com 7 1 2 Hardware Introduction Figure 1 MYK2011_100 View 1 2 1 Pins Definition Figure 2 MYK2011_100 Pins Map Table 2 MYK2011_100 Pins Definition Pin Describtion Net Name Signal Type Comments 1 17 32 48 Ground GND Power 2 Debug Pin SWCLK I PD Debug functional pin ...

Page 8: ...O20 No connect if not use 21 N C No connect 22 N C No connect 23 PWM GPIO AD PWM_5 I O GPIO23 No connect if not use 24 N C No connect 25 Power Control Switch PWR_SW I PU Leave it no connect 26 N C No connect 27 SPI Interface AD PWM SPI_MISO I GPIO27 No connect if not use 28 SPI Interface PWM SPI_CLK I O GPIO28 No connect if not use 29 SPI Interface AD SPI_CS I O GPIO29 No connect if not use 30 SPI...

Page 9: ... SmartLink APP 3 After module is powered up long press this button Low 4s to make the module recover to factory setting High Flying strongly suggest customer fan out this pin to connector or button for Manufacture and Smart Link application nLink Pin LED function 1 At wireless firmware and config upgrade mode this LED used to indicate configure and upgrade status 2 At Smart Link config mode this L...

Page 10: ...cs Technology Co Ltd www hi flying com 10 Supply current IEEE PS DTIM 100ms 12 mA Output high voltage Sourcing 6mA 2 8 V Output low voltage Sinking 6mA 0 2 V Input high voltage 2 2 V Input low voltage 0 8 V GPIO Input pull up resistor 200 kΩ GPIO Input pull down resistor 200 kΩ ...

Page 11: ...1 2 3 Mechanical Size MYK2011_100 modules physical size Unit mm as follows Figure 3 MYK2011_100 Mechanical Dimension MYK2011_100 Module PCB symbol size mm as follows Figure 4 MYK2011_100 PCB Symbol Size 1 2 4 External Antenna MYK2011_100 module supports external antenna I PEX or SMA option for user dedicated application ...

Page 12: ...ternal antenna MYK2011_100 modules must be connected to the 2 4G antenna according to IEEE 802 11b g n standards The antenna parameters required as follows Table 3 MYK2011_100 External Antenna Parameters Item Parameters Frequency range 2 4 2 5GHz Impedance 50 Ohm VSWR 2 Max Return Loss 10dB Max Connector Type I PEX or populate directly ...

Page 13: ...indow time 168 hours 3 Recommend to oven bake with N2 supplied 4 Recommend end to reflow oven with N2 supplied 5 Baked required with 24 hours at 125 5 before rework process 6 Recommend to store at 10 RH with vacuum packing 7 If SMT process needs twice reflow 1 Top side SMT and reflow 2 Bottom side SMT and reflow Case 1 Wifi module mounted on top side Need to bake when bottom side process over 168 ...

Page 14: ...i Module User Manual Shanghai High Flying Electronics Technology Co Ltd www hi flying com 14 TAPE BOX Size 340 340 70 mm Size 340 340 350 mm inside Figure 6 Shipping Information Note 1 tape 500pcs 1 box 5 tapes 5 500 pcs 2500pcs ...

Page 15: ...t 15 Subpart B or emissions are complaint with the transmitter s rule s The Grantee will provide guidance to the host manufacturer for Part 15 B requirements if needed IMPORTANT NOTE In the event that these conditions can not be met for example certain laptop configurations or co location with another transmitter then the FCC authorization is no longer considered valid and the FCC ID can not be us...

Page 16: ...erference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20cm between the radiator your body This transmitter must not be co loca...

Page 17: ...distance of 20 centimeters between the radiator and your body Cet équipement doit être installé et utilisé avec une distance minimale de 20 centimètres entre le radiateur et votre corps Copyright High Flying May 2011 The information disclosed herein is proprietary to High Flying and is not to be used by or disclosed to unauthorized persons without the written consent of High Flying The recipient o...