background image

 

 

Friday, April 19, 2019 

 

5% 

Flashing 

Off 

Off 

Off 

 

 

Aircraft startup/shutdown instructions 

Startup:  Insert  the  aircraft  battery  into  the  aircraft  battery  compartment  after  it  is 
turned on (please insert the battery into battery compartment within 30 seconds after 
it  is  turned  on,  otherwise  the  battery  will  be  turned  off  automatically),  a  sound  of 
aircraft  startup  will  be  given,  and  the  light  will  be  turn  on,  indicating  the  successful 
startup. 
Shut down: unplug the battery directly to shut down. 
Restart: It can be restarted by the upper computer or unplugging the battery. 
 

飞机校准与灯语

Aircraft calibration and lamp signal 

 

I. Non-calibration status lights 

1.  After  inserting  USB  and  connecting  successfully,  the  white  light  flashes  at  high 
frequency  for  2  seconds.  (All  lights  can  be  interrupted,  and  they  will  return  to  their 
original state after flashing for 2 seconds) 
2. When the battery level is less than 5%, it flashes red 
3.  Hardware  failures  such  as  IMU,  barometer  or  magnetometer:  white,  blue  and 
purple flash. 
4. Server is not connected: the white light is normally on 
5.  Upgrading  the  flight  control  and  transmitting  the  dance  steps:  the  purple  light  is 
normally on (in  case the communication is occupied  in the process of upgrading or 
transmitting, the instructions of the upper computer may not be processed) 
6. Automatic numbering 
6.1) Activate the automatic numbering function, calibrate the No. 0 aircraft, on which 
the  red,  green  and  blue  lights  alternate  rapidly.  When  the  numbering  is  completed 
over 90%, the server will send a light control instruction, commanding the same light 
color to be displayed in the same row or in the same row and lighting red, green, and 
the secondary shift control will be performed on the lights in the same row or in the 
same row (to prevent dead lights, the rows and columns are of the same color) 
 
6.2) Series numbers that are not within the specified range of dance steps (i.e., the 
number  of  aircrafts  are  more  than  the  number  of  dance  steps):  orange-red  (RGB: 
255, 61, 0) lights will be normally on. 
6.3) After automatic numbering is stopped, all lights return to their original state. 
* Note: In the process of number matching, if the first, second, third, fourth and fifth 
lights with high priority appear in an aircraft, the automatic numbering lamp signal will 
be lit according to the lights with high priority. 
7. Manually modify the serial number (including matching the serial number through 
USB), and the blue color is normally on for 4 seconds after successful matching. 
8. When the upper computer selects the aircraft, the orange-red (RGB: 255, 61, 0) 
light flashes; when the selection is closed, the light goes off; if there is an instruction 
from the upper computer, it will light up according to the instruction. 
9. Prepare for take-off: the forest green is normally on. 
10. Countdown to take-off: the indigo is normally on. 

Summary of Contents for EMO

Page 1: ...Friday April 19 2019 1 EMO Formation UAV User Guide V1 0 0...

Page 2: ...CAUTION is intended to remind the do s and don ts during use Losses may be caused if operations are not performed as required TIPS is intended to facilitate a better experience on product functions an...

Page 3: ...highlights Centimeter level positioning the most advanced RTK centimeter level positioning technology was adopted 5 8G Wifi 5 8G Wifi was used for networking communication facilitating communication t...

Page 4: ...zed This could eliminate the tedious procedures of placing numbers Aerial pause the aerial UAV can be controlled by the ground host computer to pause at a specific position and can restart and go arou...

Page 5: ...titude 300m Maximum flight distance 800 1000m Light power 0 22W adjustable Maximum luminous flux 840lm Minimum flight spacing 1 5m Communication mode 5 8G WIFI Working temperature 20 50 C IMU Double I...

Page 6: ...Friday April 19 2019 6 1 Motor 2 Blade 3 Lampshade 4 Protective cover 5 RTK antenna 6 Battery compartment 7 Battery compartment locking device 8 Battery switch 9 Battery level indicator...

Page 7: ...battery is on press and hold the battery on off key until the power indicator goes out 2 In the battery on state if it is unable to detect the connection between the battery and the aircraft the batt...

Page 8: ...ring 6 1 Activate the automatic numbering function calibrate the No 0 aircraft on which the red green and blue lights alternate rapidly When the numbering is completed over 90 the server will send a l...

Page 9: ...tion magnetometer Send the magnetic calibration instruction through the upper computer and rotate the aircraft as shown in the following figures Horizontal calibration Vertical calibration 1 Horizonta...

Page 10: ...flashes for three seconds Propeller replacement The new propeller blades must rotate in the same direction as the original propeller blades Attention should be paid to clockwise and counterclockwise...

Page 11: ...he user promises to use the product and supporting software only for legitimate purposes and agrees to abide by these terms and any relevant policies or guidelines that may be formulated by HighGreat...

Page 12: ...eas 9 Operator s operation error or subjective judgment error 10 Improper storage such as being subjected to strong impact or extrusion or being placed in an inappropriate environment e g water ingres...

Page 13: ...se of the used battery according to the instructions The Type C port of the device can only be connected with devices with specified communication port and it is forbidden to connect it to some other...

Page 14: ...nistrative regulations public order and good customs in the region where the products are used The copyrights of this product and manual belong to HighGreat No organization or individual may copy repr...

Page 15: ...e Shenzhen HighGreat Innovation Technology Development Co Ltd Address 2 F Building 6 Yuanlingzi Industrial Zone Hengping Road Yuanshan Street Longgang District Shenzhen E mail TEL 400 888 9686 WeChat...

Page 16: ...requency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur...