O P E R A T O R M A N U A L
4
Operating Environment
Indoor/Outdoor-fair weather
Altitude: 100% of rating;Sea-level, up to 5000ft.(approx.1500M). The output power is
de-rated 10% above 5000 ft. altitude, 20% above 12,000 ft.( approx. 3600M), and
30% above 15,000 ft.(approx. 4500M)
Storage Temperature: -20
°
C to 70
°
C(-4
°
F to 158
°
F)
Operating Temperature: -5
°
C to 45
°
C(22
°
F to 113
°
F) Output power is de-rated
linearly by 15% from 30 to 45
°
C ambient.
Maximum Relative Humidity: 80% up to 31
°
C(88
°
F), decreasing linearly to 50% at
40
°
C(104
°
F)
Mains supply fluctuation: +/-10% of rated voltage
Installation: Category II
Pollution: Degree 2
WARNING
DO NOT OPERATE THE VLF HIPOT SET IF THE HIGH VOLTAGE TANK IS 5
°
OR MORE
FROM LEVEL.
IF THE UNIT IS OPERATED OUT OF LEVEL, OVERHEATING AND INTERNAL ARCING MAY OCCUR.
DO NOT STORE OR TRANSPORT VLF HIGH VOLTAGE SECTION
ON IT’S SIDE