APPLIANCE OPERATION MANUAL
-24
PROCEDURE FOR CONVERTING YOUR HIGHLAND COOK TOP FROM NATURAL GAS TO LP GAS
1.
Ensure that the correct LP gas test point has been fitted and that there is a ready supply of LP gas to enable
you to correctly set the flames on each of the burners.
2.
Follow the instructions for removal of the hob as detailed in the servicing instructions. Ensure the Natural
gas regulator is replaced with an LP gas regulator usually supplied at the cylinder.
3.
To convert the burner you will need to replace the main injector , auxiliary injector and the by pass screw.
See above table for sizes.
The bypass screws for the wok requires replacing to achieve the correct minimum settings. Remove the bypass
screws and replace as follows
0.9mm goes to 0.52mm main burner.
0.45mm goes to 0.3mm auxiliary burner
The turn down setting for the A<B and C burners is adjusted through the screw in the top of valve.
Assemble and test.
PROCEDURE FOR CONVERTING YOUR
HIGHLAND COOK TOP FROM NATURAL
GAS TO LP GAS
PLEASE READ AND KEEP FOR FUTURE REFERENCE
Note:
It is recommended this procedure is done by the authorised factory not in
domestic situations