51
2.
Select the proper controller using the drop down menu on the top left
3.
Click the
SHI
tab
4.
Click
SMART
on the desired disk
5.
Click
Enable
to enable SMART monitoring
Disabling SMART monitoring
You have the option the disable SMART monitoring on each individual disk.
To disable:
1.
Select the proper controller using the drop down menu on the top left
2.
Click the
SHI
tab
3.
Click
SMART
on desired disk
4.
Click
Disable
Note
: Disabling SMART will prompt the Storage Health Inspector to change the disk status to
‘Failed’. The alarm will
not
alert you when this setting is changed. And any potential warnings
due to S.M.A.R.T attribute technology will not
Changing HDD Temperature Threshold
To ensure hard disk temperatures remain cool, enable SMART to monitor disk temperatures. In
SHI
, you can set a threshold so that the WebGUI or controller alarm (if enabled) can warn you
when physical disks get too hot.
1.
Log in to WebGUI
2.
Select the controller from the drop down on the top left
3.
Click
SHI
4.
Type the desired hard disk temperature threshold (
°𝐹
)
5.
Click
Set
Utilizing the Health Inspector Scheduler