background image

6

SYMBOLS

WARNING

 

The following show symbols used for the machine. 

Be sure that you understand their meaning before 

use.

CF18DSL / CF18DSAL

: Cordless Steel Rebar Cutter

Read all safety warnings and all instructions.

Always wear eye protection.

Wear head protection

No open 

fl

 ame; Fire, open ignition source and 

smoking prohibited

Keep your hands away

Keep your face away

Direct current

V

Rated voltage

D max The maximum diameter that can be cut

Disconnect the battery

Light switch: Cannot be used with this tool

Switching ON

Operates the same on either side

Remaining battery indicator switch

The battery remaining power is nearly empty. 

Recharge the battery soonest possible
The battery remaining power is a half.

The battery remaining power is enough.

Bites into rebar

Prohibited action

 

Warning

STANDARD ACCESSORIES

In addition to the main unit (1 unit), the package contains the 

accessories listed on page 8.

Standard accessories are subject to change without notice.

APPLICATIONS

Cutting rebar to be used for reinforcing concrete

SPECIFICATIONS

Model

CF18DSL

CF18DSAL

Voltage

18 V

Cutting capacity

Up to 16 mm 

diameter

Up to 20 mm 

diameter

Cutting speed

4 sec.

6.5 sec.

Max. Rebar 

hardness

Tensile strength 490 N/mm

2

Head angle of 

rotation

345°

360°

Dimensions

(L×W×H)

370 × 90 × 306 mm

(without side handle)

413 × 103 × 316 mm

(without side handle)

Weight

6.6 kg (BSL1850) 9.4 kg (BSL1850)

NOTE

  Due to HiKOKI’s continuing program of research and 

development, the speci

fi

 cations herein are subject to 

change without prior notice.

CHARGING

For rechargable batteries, please charge in according to 

the handing instruction of the charger which you are using. 

(

Fig.3

)

REGARDING ENVIRONMENT AND 

CONDITIONS OF USE

This tool operates on oil pressure.

When used during the winter season or in cold conditions 

the hydraulic oil’s viscosity will excessively rise to dull the 

tool’s operation.

In such cases, run the tool through a warm-up operation 

prior to use.

How to run a warm-up operation

Without setting up a rebar, switch on the tool and let it 

continuously run for 30 to 60 seconds.

WARNING

  Do not place your hands in the vicinity of the piston 

during warm-up operation.

Depending on the environment and conditions of use, the 

hydraulics may heat up (over 50°C). This can lower the 

viscosity of the hydraulic oil and reduce its cutting power. 

If this occurs, allow the tool to cool down and then resume 

operation.

MOUNTING AND OPERATION

Action

Figure

Page

Removing and inserting the battery

2

9

Charging

3

9

Switch operation

4

10

Regarding the switch panel

(Remaining battery indicator)

5

10

Regarding the rotation mechanism of 

the tool head

6

10

Cutting

7

11

If the tool bites into a rebar

8

12

Changing the cutter block*

9

12

0000Book̲CF18DSL.indb   6

0000Book̲CF18DSL.indb   6

2017/12/05   10:26:34

2017/12/05   10:26:34

Summary of Contents for CF 18DSAL

Page 1: ...CF 18DSL CF 18DSAL CF18DSL CF18DSAL Handling instructions 0000Book CF18DSL indb 1 0000Book CF18DSL indb 1 2017 12 05 10 26 32 2017 12 05 10 26 32 ...

Page 2: ... may create a risk of fire when used with another battery pack b Use power tools only with specifically designated battery packs Use of any other battery packs may create a risk of injury and fire GENERAL POWER TOOL SAFETY WARNINGS WARNING Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all w...

Page 3: ... flammable and the following precautions should be taken to avoid fire Do not remove the pump cases oil plug during operation or when the tool is warm Replenish hydraulic oil after the tool has sufficiently cooled When replenishing hydraulic oil choose a location where there are no combustibles in the vicinity and avoid any spilling Should the oil be spilled make sure to thoroughly wipe it up Do not...

Page 4: ... a location out of the reach of children 13 Use the battery correctly in accordance with its specifications ADDITIONAL SAFETY WARNINGS 1 If the switch does not return to its original position immediately discontinue use and arrange for repairs with the HiKOKI Authorized Service Center 2 Do not strike or apply strong impact to the switch panel Doing so can lead to damage 3 While operating the tool ...

Page 5: ...may cause eye problems 2 If liquid leaks onto your skin or clothes wash well with clean water such as tap water immediately There is a possibility that this can cause skin irritation 3 If you find rust foul odor overheating discolor deformation and or other irregularities when using the battery for the first time do not use and return it to your supplier or vendor WARNING If a conductive foreign m...

Page 6: ...andle 413 103 316 mm without side handle Weight 6 6 kg BSL1850 9 4 kg BSL1850 NOTE Due to HiKOKI s continuing program of research and development the specifications herein are subject to change without prior notice CHARGING For rechargable batteries please charge in according to the handing instruction of the charger which you are using Fig 3 REGARDING ENVIRONMENT AND CONDITIONS OF USE This tool o...

Page 7: ...ys keep carbon brushes clean and ensure that they slide freely whithin the brush holders NOTE When replacing the carbon brush with a new one be sure to use the HiKOKI Carbon Brush Code No 999100 7 Replacing carbon brushes Fig 11 Take out the carbon brush by first removing the brush cap and then hooking the protrusion of the carbon brush with a flat head screw driver etc When installing the carbon ...

Page 8: ...8 4 mm 5 mm CF18DSL NK 1 1 1 1 1 CF18DSAL NK 1 1 1 1 1 0000Book CF18DSL indb 8 0000Book CF18DSL indb 8 2017 12 05 10 26 35 2017 12 05 10 26 35 ...

Page 9: ...9 1 CF18DSL CF18DSAL 9 9 6 6 0 0 3 3 4 4 8 8 7 7 5 5 1 1 2 2 2 3 1 2 i 1 2 0000Book CF18DSL indb 9 0000Book CF18DSL indb 9 2017 12 05 10 26 35 2017 12 05 10 26 35 ...

Page 10: ...10 4 Ϩ 5 6 CF18DSL 345 360 CF18DSAL 0000Book CF18DSL indb 10 0000Book CF18DSL indb 10 2017 12 05 10 26 36 2017 12 05 10 26 36 ...

Page 11: ...11 7 2 CF18DSL 345 360 CF18DSAL 30 cm 30 cm 7 7 7 7 7 7 0000Book CF18DSL indb 11 0000Book CF18DSL indb 11 2017 12 05 10 26 36 2017 12 05 10 26 36 ...

Page 12: ...12 8 CF18DSL 60 60 CF18DSL CF18DSAL CF18DSAL 4 4 4 4 9 7 u u u u u u y 7 7 1 3 3 y q q q w 0000Book CF18DSL indb 12 0000Book CF18DSL indb 12 2017 12 05 10 26 36 2017 12 05 10 26 36 ...

Page 13: ...13 10 Ϩ Ϩ D max 2 CF18DSL CF18DSL CF18DSAL CF18DSAL t e t e r 5 0000Book CF18DSL indb 13 0000Book CF18DSL indb 13 2017 12 05 10 26 36 2017 12 05 10 26 36 ...

Page 14: ...14 11 ⓒ ⓐ ⓑ 6 6 3 mm 9 5 mm 0000Book CF18DSL indb 14 0000Book CF18DSL indb 14 2017 12 05 10 26 37 2017 12 05 10 26 37 ...

Page 15: ...15 UC18YFSL 14 4V 18V 329897 18V Li ion 944458 944459 931161 306254 306295 999100 338710 0000Book CF18DSL indb 15 0000Book CF18DSL indb 15 2017 12 05 10 26 37 2017 12 05 10 26 37 ...

Page 16: ...806 Code No C99715011 G Printed in China Shinagawa Intercity Tower A 15 1 Konan 2 chome Minato ku Tokyo Japan 0000Book CF18DSL indb 16 0000Book CF18DSL indb 16 2017 12 05 10 26 37 2017 12 05 10 26 37 ...