CA/CE-Series GigE Area Scan Camera
·
User Manual
28
You can set proper value in
Trigger Delay
, and its range is from 0 μs to 16000000 μs.
Figure 7-16
Set Trigger Delay
7.5.3 Set Trigger Cache Enable
The camera has the function of Trigger Cache Enable. During the triggering process, if the camera
receives new trigger signal, it will save and process the signal if you enable this function. Trigger
cache enable can save up to 2 trigger signals.
You can set Trigger Cache Enable as shown below.
Steps:
1.
Click
Acquisition Control > Trigger Cache Enable
.
2.
Enable
Trigger Cache Enable
.
Figure 7-17
Enable Trigger Cache Enable
If the camera receives the 1st trigger signal first, and the camera receives the 2nd trigger signal
during processing the 1st trigger signal.
Disable Trigger Cache Enable: the 2nd trigger signal will be filtered without processing.
Enable Trigger Cache Enable: the 2nd trigger signal will be saved.