11.4.2 Effective Bandwidth and Setting
calculation of 1000M network port’s image loading bandwidth is:
BandWidth=((PacketSize
–
(IP+UDP+GVSP Header))/(Pack MA CRC+Packet-Delay))
* 1000M/bps
. Normally, IP/UDP/GVSP Header occupies 36 bytes, MAC Header occupies 14 bytes,
and CRC occupies 4 bytes.
Taking setting packet size 1500 and packet delay 400 as an example, the actual network bandwidth
is:
BandWidth=(1500-36)/(1500+14+4+400)*1000Mbps=759.36 Mbps.
The actual network
bandwidth is smaller than the theoretical one because of the network message, GVCP, GCSP leader,
Trailer and any other overheads.
You can set Packet Size (
GEV SCPS Packet Size
) value and Packet Delay (
GEV SCPD
) value by input
value in the input box, as shown below.
Figure 11-7
Set Packet Size and Packet Delay
11.5 Update Firmware
The camera supports firmware updating via the MVS client.
Before updating, make sure power cable and others are properly connected.
Please use the firmware package of the corresponding camera model for updating.
Steps:
1.
Click
Tool > Firmware Updater
to open the update interface.
2.
Click
to select the camera you want to update.
3.
Click
to select the update file in the local computer.
Summary of Contents for CA Series