CameraLink Area Scan Camera
·
User Manual
37
Parameter Name
Parameter Symbol Value
Input Rising Delay
TDR
1.8 μs to 4.6μs
Input Falling Delay
TDF
16.8 μs to 22 μs
Make sure the input voltage is not from 1 VDC to 1.5 VDC as the electric status between these
two values are not stable.
The breakdown voltage is 30 VDC, and keep voltage stable.
7.1.2 Line 1 Opto-isolated Output Circuit
The Line 1 opto-isolated output circuit in camera I/O control is shown below.
GPO
Line 1+
Line 1-
Figure 7-3
Line 1 Internal Circuit
The maximum output current of Line 1 is 25 mA.
Logic 1
Output Level
Logic 0
Output Level
Internal
Logic
TDR
TDF
Figure 7-4
Output Logic Level
Opto-isolated output electric feature is shown in below (when the external voltage is 3.3 VDC and
the external resistance is 1 K).
Summary of Contents for CameraLink Area Scan Camera
Page 1: ...CameraLink Area Scan Camera User Manual ...
Page 95: ...UD14755B ...