CameraLink Area Scan Camera
·
User Manual
40
Table 7-5
Parameter of Output Logic Level Low
External Voltage
External Resistance
VL (GPIO2)
3.3 V
1 KΩ
160 mV
5 V
1 KΩ
220 mV
12 V
1 KΩ
460 mV
24 V
1 KΩ
860 mV
30 V
1 KΩ
970 mV
The maximum current is 25 mA and the output impedance is 40 Ω.
When the voltage of external resistance (1KΩ) is pulled up to 5V, the logic level and electrical
feature of configuring Line 2 as output are shown below.
Logic 1
Output Level
Logic 0
Output Level
Internal
Logic
TDR
TDF
TF
TR
Figure 7-7
Output Logic Level
Table 7-6
Electrical Feature of Line 2 Output
Parameter Name
Parameter Symbol Value
Output Logic Level Low
VL
220 mV
Output Logic Level High VH
4.75 V
Output Rising Time
TR
0.06 μs
Output Falling Time
TF
0.016 μs