CameraLink Area Scan Camera
·
User Manual
41
Parameter Name
Parameter Symbol Value
Output Rising Delay
TDR
0 μs to 4μs
Output Falling Delay
TDF
< 1 μs
7.2 I/O Wiring
The camera has different appearances and I/O interfaces with varied models. Here we take type II
camera as an example to introduce I/O wiring.
For specific camera appearance, cable color and I/O wiring, please refer to the actual one you got.
7.2.1 Line 0 Wiring
When the camera uses Line 0 as hardware trigger source, wirings are different with different
external devices of input signal.
PNP Device
Camera Power
Supply
Opt-Iso in
Camera Power
Ground
PWR
VCC
Device Power
Supply
Signal Line
Device Power
Ground
PNP Device
I/O Ground
GND of PWR
GND of VCC
Figure 7-8
Line 0 Connecting to PNP Device
NPN Device
If the VCC of NPN device is 24 VDC, and it is recommended to use 1 KΩ to 4.7 KΩ pull-up resistor.
If the VCC of NPN device is 12 VDC, and it is recommended to use 1 KΩ pull-up resistor.
Summary of Contents for CameraLink Area Scan Camera
Page 1: ...CameraLink Area Scan Camera User Manual ...
Page 95: ...UD14755B ...