CameraLink Area Scan Camera
·
User Manual
15
Figure 3-5
Device Tap Geometry
For cameras of different models, the mode that the camera supports may differ. Pease refer to the
specification of the camera for detailed information.
3.3 Serial Port Tool
Purpose:
Apart from the MVS client and frame grabber software, the serial port tool can also be used to
detect camera status, read and set camera parameters.
You can set camera parameters by connecting CameraLink serial port cable. When accessing the
camera or using the terminal in the application software, you are required to set the parameters as
follows.
Table 3-5
Serial Port Tool
Serial Port Parameter
Value
Baud Rate
9600 bps
Data Bit
8-bit
Parity Bit
None
Stop Bit
1-bit
Stream Control
None