Off refers to the internal trigger mode, and On refers to the external trigger mode.
5.3 External Trigger Mode
5.3.1 Set External Trigger Source
There are 4 types of external trigger sources, including software trigger, hardware trigger, counter
trigger and frame grabber trigger. Their principle and parameter setting are shown below.
Table 5-2
Principle and Parameter of External Trigger Mode
External Trigger
Source
Parameter
Parameter Value
Principle
Software trigger
Acquisition Control >
Trigger Source
Software
The software sends trigger
signal to the camera via
CameraLink interface to
acquire images.
Hardware trigger
Acquisition Control >
Trigger Source
Line 0, Line 2
External device connects
camera via camera I/O
interface. External device
sends trigger signal to
camera to acquire images.
Counter trigger
Acquisition Control >
Trigger Source
Counter 0
The counter sends trigger
signal to the camera to
acquire images.
Frame grabber
trigger
Acquisition Control >
Trigger Source
CC 1/2/3/4
The frame grabber sends
trigger signal to the camera
to acquire images.
You can set trigger source as shown below.
Steps:
1.
Click Acquisition Control > Trigger Source.
2.
Select trigger source according to actual demands.