CameraLink Line Scan Camera
·
User Manual
32
Trigger Activation Parameter
Parameter Value
Principle
Level high
Acquisition Control >
Trigger Activation
Level High
Level High refers to the level
high of the trigger signal is valid.
The trigger is active as long as
the trigger signal is high.
Level low
Acquisition Control >
Trigger Activation
Level Low
Level Low refers to the level low
of the trigger signal is valid. The
trigger is active as long as the
trigger signal is low.
You can set trigger activation as shown below.
Steps:
1.
Click Acquisition Control > Trigger Activation.
2.
Select Falling Edge, Rising Edge, Level High or Level Low as Trigger Activation.
Figure 6-29
Select Trigger Activation
6.4.4 Shaft Encoder Counter
There are 2 types of encoder counter modes, including Ignore Direction and Follow Direction. The
former one records data of all directions. The latter one records forward data once, and repeated
data is not recorded.
You can set camera max. value of counting (0 to 32767) via Encoder Counter Max. After reaching
the max. value, it will be cleared automatically or you can clear manually.