ID3000 Series Smart Code Reader User Manual
31
7. Click Execute in Adjust Start. The device will automatically acquire images and perform self-
adaptive adjustment, and stop acquisition after adjustment is completed.
Note
If the adjustment completed, the client software displays the spent time and prompts adjustment
succeeded. If the adjustment failed or is timeout, the client software prompts adjustment failure
or timeout.
Figure 8-8 Set Self-Adaptive Adjustment
8.1.6 Set Mirror X
The device supports the mirror X function. If this function is enabled, the image will be reversed in
a horizontal way.
Go to Image Settings, click All Features, and you can see the Mirror X.
Note
This function is enabled by default, and it may differ by device models.
8.1.7 Set Test Pattern
Test pattern helps troubleshooting image problems and images in the test pattern are only for test.
When exceptions occur in images acquired by the device in real time, you can check if images in the
test pattern have similar problems to determine the cause of an exception.
Note
●
The test pattern is available in the test or raw device mode.
●
Specific parameters of this function may differ by device models.
Go to Image Settings, click All Features, find Test Pattern in Other Features, and set Test Pattern
according to actual demands.