ID3000 Series Smart Code Reader User Manual
54
If the burst of a frame stops, the output signal will be triggered. When you select Frame Burst Stop
Active as Line Out Activation Event, you can set its output delay time and duration.
Line Out Delay Time
It sets the delay time for outputting the output signal.
Line Out Duration
It sets the time duration of the output signal.
Figure 8-40 Select Frame Burst Stop Active
Select Exposure Start Active
Note
For different models of device, when selecting Exposure Start Active as Line Out Activation Event,
the specific parameters may be different. The actual product you purchased shall prevail.
If you select Exposure Start Active as Line Out Activation Event, you can set its output delay time,
duration, and ahead time.
Line Out Delay Time
It sets the delay time for outputting the signal.
Line Out Duration
It sets the duration for outputting the signal.
Line Out Ahead Time
It sets the ahead time for outputting the signal.