ID6000 Series Smart Code Reader User Manual
35
reading timeout duration or max. barcode amount to be read to stop trigger. After stopping
trigger is completed, the device cannot make response to trigger again.
Stop Trigger via IO
You can stop a trigger via IO: Enabling IO Stop Trigger Enable first, select specific sources from IO
Stop Trigger Selector, and then set the trigger polarity as the condition to stop trigger.
Figure 7-17 Stop Trigger via IO
When selecting SoftwareTriggerEnd as IO Stop Trigger Selector, you can click Execute in Software
Stop Trigger to stop current trigger.
Figure 7-18 Software Trigger End
Stop Trigger via Serial
When the specified serial port receives the specified string text, the trigger will be stopped. The
client software sends stop trigger command to the device after Serial Stop Trigger Enable is
enabled.
You should enter Serial Stop Trigger Text, Serial Baudrate, Serial Data Bits, Serial parity, and
Serial Stop Bits according to actual demands. The Serial Baudrate includes 4800, 9600, 19200,