ID7000 Series Smart Code Reader User Manual
15
The
device’s
/- are differential inputs, and their internal circuit is as follows.
Figure 4-13 Internal Circuit of Differential Input
Note
The input voltage ranges from 5 VDC to 30 VDC.
4.2.2 Output Signal
The device's LineOut 0/1 are opto-isolated outputs, and their internal circuit is as follows.
Note
●
The output voltage ranges from 5 VDC to 30 VDC.
●
The maximum output current is 45 mA.
●
Do not directly connect with inductive load (e.g. DC motor, etc.) when outputting.
Figure 4-14 Internal Circuit of Output Signal