ID7000 Series Smart Code Reader User Manual
41
Before Debounce
After Debounce
Trigger_in1
Trigger_in2
Trigger_in3
Trigger_in2
Trigger_in3
Debouncer Time
Debouncer Time
Debouncer Time
t
1
t2
t1
t
4
t1
t
6
(t1>t2, trigger signal is ignored)
(t1<t4, trigger signal outputs after delaying t1) (t1<t6, trigger signal outputs after delaying t1)
Figure 9-11 Debouncer Sequence Diagram
Note
If the configured debouncer time is larger than the pulse width of trigger signal, the trigger signal
will be ignored. Otherwise, the trigger signal will be outputted after delay.
Line Trigger Mode
Steps
1. Right click the device in the
Device Connection
, and click
Feature Tree
.
2. Go to
Trigger and IO Control
→
Trigger Selector
.
3. Set
Trigger Mode
as
On
after selecting
Line Start
as
Trigger Selector
.
4. Select
Trigger In Source
according to actual demands.
Note
For specific trigger sources, refer to the actual device you got.
5. Set
Debouncer Time
after selecting
LineIn *
as
Trigger Source
.
Figure 9-12 Set Debouncer Time