SC2000 Series Vision Sensor User Manual
33
Load Feature Template
Steps
1. Go to Solution → Tool → Template, and click Upload to upload local template to create feature
template.
Parameter Settings
Min. Match Score
The match score refers to the similarity between feature template and targets in the searched
images. The min. match score refers to the similarity threshold. The searched target will be
searched when the similarity reaches this threshold. This parameter also affects the search
speed.
Max. Match Quantity
It is the max. target quantity that can be searched.
Match Polarity
It includes Considered and Ignored.
Angle
It is the angle range of searched targets. The edited template is the reference.
Scale
Zoom in and zoom out with same scale. It is applied for the target and template with certain
percentage.
Max. Overlap Rate
The higher the overlap rate, the larger the overlap area that can be tolerated. The increase of
overlap rate may reduce the search speed, and introduce false detections.
Sort
You can specify the order in which the target is searched. It includes No Sort, Score: High to Low,
Angle: Large to Small, X: Small to Large, Y: Small to Large, X: Small to Large, Y: Small To Large;
Y: Small to Large, X: Small to Large.
Overtime Control
When the time exceeds the time set by overtime control, the search will stop and no search
result will be returned. If it is set as 0, the overtime control function is disabled.