SC2000 Series Vision Sensor User Manual
48
●
The ROI can be rectangle only.
Fixture
After enabling it, you can subscribe fixture tool. See Fixture Settings for details.
Note
If you want to use fixture tool in measuring brightness, you should set fixture tool first.
Figure 8-29 Brightness Measure
Result Display
In display area, you can set different judge methods of image detection result, including max.
value, min. value, mean value, standard deviation, etc.
In Judge Method, enable Judge by Max. Value, Judge by Min. Value, Judge by Mean. Value,
Judge by Standard Deviation, Judge by Contrast, and enter corresponding range according to
actual demands. You can also enable Reverse Result to reverse result.
In Image Display, click
to display or not display detection area. Click
to edit OK color, NG
color, and transparency.
In OSD, enable Display Test to set text's color, front size, transparency, position X, and position Y.