SC7000 Series Smart Camera User Manual
25
Level High: The level high of the trigger signal is valid. As long as the trigger signal is in level high,
the device is in image acquisition status.
Level Low: The level low of the trigger signal is valid. As long as the trigger signal is in level low, the
device is in image acquisition status.
Set Trigger Delay
The trigger delay function allows the device to add a delay between the receipt of trigger signal
and the moment the trigger becomes active. The range of this parameter is from 0 to 1000000 μs.
Note
This parameter is available only when selecting rising or falling edge as the trigger type. If level
high or level low is selected as the trigger type, you can set trigger start delay or end delay
according to actual demands.
Set Filter Time
The external trigger input signal of the device may have signal bounce that may cause false trigger.
Thus, it is necessary to set filter time. The range of this parameter is from 0 to 1000000 μs.
Figure 8-8 Set Related Parameters about External Trigger Mode
8.2.5 Enable Communication Trigger Mode
The device also supports triggering by receiving communication string.
Select ON as Trigger Mode, select COMMUNICATION as Trigger Source, and enter String and
Delay according to actual demands.