background image

No. 

Description 

DIP Switch Status 

(Only  available  for  CPU  card 
reader.) 

0: read file in card. 

Wiegand  protocol  or  RS-485 
protocol. 

1: Wiegand protocol; 
0: RS-485 protocol. 

Wiegand Protocol   
(available when No. 6 is 1) 

1:  Wiegand  protocol 
of 26-bit; 
0:  Wiegand  protocol 
of 34-bit. 

Matched Resistance   
(available for RS-485 protocol) 

1: Enable; 
0: Disable. 

3.3

 

Definition of Cable 

The description of 10 cables is shown below. 

Table 3-3

 

Description of Cable 

Color 

Description 

Orange 

Wiegand ERR (available for Wiegand Protocol) 

Brown 

Wiegand OK (available for Wiegand Protocol) 

White 

Wiegand W1 (available for Wiegand Protocol) 

Green 

Wiegand W0 (available for Wiegand Protocol) 

Blue 

RS-485 - 

Yellow 

RS-485 + 

Red 

PWR (DC +12V) 

Black 

GND 

Gray 

TAMPER Control 

Purple 

Beep Control (available for Wiegand Protocol) 

Summary of Contents for 6954273653712

Page 1: ...DS K1108 Series Card Reader User Manual UD01841B ...

Page 2: ...r using and managing the product Pictures charts images and all other information hereinafter are for description and explanation only The information contained in the Manual is subject to change without notice due to firmware updates or other reasons Please find the latest version in the company website http overseas hikvision com en Please use this user manual under the guidance of professionals...

Page 3: ...PRODUCT SHALL BE WHOLLY AT YOUR OWN RISKS HIKVISION SHALL NOT TAKE ANY RESPONSIBILITES FOR ABNORMAL OPERATION PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER ATTACK HACKER ATTACK VIRUS INSPECTION OR OTHER INTERNET SECURITY RISKS HOWEVER HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED SURVEILLANCE LAWS VARY BY JURISDICTION PLEASE CHECK ALL RELEVANT LAWS IN YOUR JURISDICTION BEFORE...

Page 4: ...ONARY TIPS 2 CHAPTER 2 INTRODUCTION 3 2 1 FRONT VIEW 3 2 2 REAR VIEW 4 CHAPTER 3 INSTALLATION 4 3 1 INSTALLING PSAM CARD 4 3 2 INTRODUCTION FOR DIP SWITCH 5 3 3 DEFINITION OF CABLE 6 3 4 WIRING CABLES 7 CHAPTER 4 SOUND PROMPT AND INDICATOR 9 ...

Page 5: ...V range 10 10 DC power supply which is nonswitched and linear To guarantee the communication between the controller and the card reader you must use RVVP cable above 0 5 to connect them If the card reader is installed outside or in environment easy to permeable it is advisable to install a waterproof shield If you need to install several card readers the distance among them must over 30cm To reduc...

Page 6: ...access controller via either RS 485 protocol or Wiegand protocol And a build in tamper proof module helps to protect card reader from malicious damage As to the physical appearance the PC ABS material makes water proof and dust proof possible in poor environment 2 1 Front View DS K1108EK MK SK DS K1108E M S Figure 2 1 Front View of DS K1108 Series ...

Page 7: ...w Figure 2 2 Rear View of DS K1108 Series Chapter 3 Installation 3 1 Installing PSAM Card PSAM card slot is only available for CPU card reader Insert the PSAM card into the slot according to the direction shown below ...

Page 8: ...P Switch Module Table 3 1 Description of DIP Switch Icon Description Represent 1 in binary mode Represent 0 in binary mode For example binary value of the following status is 0000 1100 Figure 3 3 DIP Switch Module Table 3 2 Description of DIP Switch No Description DIP Switch Status 1 4 Address of RS 485 1 1 0 0 5 Read card No or file in card 1 read card No ...

Page 9: ...nce available for RS 485 protocol 1 Enable 0 Disable 3 3 Definition of Cable The description of 10 cables is shown below Table 3 3 Description of Cable Color Description Orange Wiegand ERR available for Wiegand Protocol Brown Wiegand OK available for Wiegand Protocol White Wiegand W1 available for Wiegand Protocol Green Wiegand W0 available for Wiegand Protocol Blue RS 485 Yellow RS 485 Red PWR DC...

Page 10: ... 485 communication mode 1 Set the DIP switch of No 6 as 0 2 Set the DIP switch of No 1 5 for RS 485 address and reading card mode For details please refer to 3 2 Introduction for DIP Switch 3 Wire the cable between controller and card reader as shown below Figure 3 4 Wiring for RS 485 Communication Mode Steps for Wiegand communication mode ...

Page 11: ... DIP switch of No 5 and 7 for reading card mode and Wiegand protocol For details please refer to 3 2 Introduction for DIP Switch 3 Wiring the cable between controller and card reader as shown below Figure 3 5 Wiring for Wiegand Communication Mode ...

Page 12: ...on of Prompt Sound Sound Prompt Description One beep Swiping card prompt Pressing keys prompt Prompt for too long card No input by pressing keys Time out prompt for pressing keys or swiping card For authentication prompt for entering the password after swiping the card Two rapid beeps The operation of pressing keys or swiping card is valid Three slow beeps The operation of pressing keys or swiping...

Page 13: ...r entering the password after swiping the card Solid green for 2s The operation of pressing keys or swiping card is valid Solid red Card reader is working normally Red and blink for 3 times The operation of pressing keys or swiping card is invalid Red and blinking For RS 485 protocol Registering failed or card reader is offline ...

Page 14: ...11 ...

Reviews: