6. Optional: Set the minimum size and the maximum size for the target to improve detection
accuracy. Only targets whose size are between the maximum size and the minimum size trigger
the detection.
1) Click Max. Size, and drag the mouse on live image. If you want to change the size, click the
button and draw again.
2) Click Min. Size, and drag the mouse on the live image. If you want to change the size, click the
button and draw again.
7. Set detection parameters.
Sensitivity
It stands for the sensitivity of detecting an target. The higher the value of
sensitivity is, the more easily the target is detected.
Threshold
Threshold stands for the time of the target loitering in the region. If the time
that she/he stays in the region exceeds the threshold, the alarm is triggered.
Detection
Target
You can specify the object type, and the device only detects the selected
type of objects.
Figure 8-4 Draw Area
8. Click Save.
9. Repeat above steps to set other detection areas.
10. Set arming schedule. See Set Arming Schedule .
11. Set linkage method. See Linkage Method Settings .
Network Speed Dome User Manual