HD Video and Audio Decoder User Manual
DS-6900UDI Decoder User Manual
66
1.
Log in to the camera via the
Web browser.
2.
Click
Configuration
>
Advanced Configuration
>
System
>
VCA Resource Type
to enter
the VCA Resource Type configuration interface.
3.
Select
Temperature Measurement and Behavior Analysis
as the VCA Resource Type.
4.
Click
Save
to save the settings.
Configure temperature measurement.
Step 2
1.
Click
Configuration
>
Advanced Configuration
>
Temperature Measurement
>
Temperature Measurement Configuration
to enter the Temperature Measurement
configuration interface.
Temperature Measurement Configuration
Figure 5-35
2.
Check the checkboxes of the interface to set the temperature measurement
configurations.
Enable Temperature Measurement:
Check the checkbox to enable temperature
measurement function.
Display Temperature Info. on Stream:
Check the checkbox to display temperature
information in live view.
Add Original Data on Capture:
Check the checkbox to add original data on capture.
Add Original Data on Stream:
Check the checkbox to add original data on stream.
3.
Select the
Data Refresh Interval
from 1s to 5s.
4.
Select the
Unit
to display temperature with Degree Celsius (°C)/Degree Fahrenheit
(°F)/Degree Kelvin (K).
5.
Configure the
Temperature Range
.
6.
Click
Save
to save the settings.
Configure the temperature measurement and alarm.
Step 3
1.
Click
Configuration
>
Advanced Configuration
>
Temperature Measurement
>
Temperature Measurement and Alarm
to enter the Temperature Measurement and
Alarm configuration interface.