6.11.8 Configure Lane Parameters
You can set the passing parameters for a person to pass through the turnstile.
Steps
1. Click Maintenance and Management → Device to enter the device list.
2. Click to enter the remote configuration page.
3. Click System → Lane Settings .
4. Set the lane parameters.
Delayed Time Duration When Closing Barrier
Set the delayed time duration when barrier is closing. The barrier will be closed after the
configured delayed time.
Max. Intrusion Duration
If a person has entered the lane or passed through the lane for more than the configured
time duration, an alarm will be triggered. 0 represents the function is disabled.
Note
The suggested minimum detection time duration is 2 s.
Overstayed Time Duration
If the device detects persons or things staying in the lane for more than the configured time
duration, an alarm will be triggered.
Max IR Obstructed Duration
Set the maximum time duration for the obstruction of the IR light. If the IR light is obstructed
for more than the configured time duration, the alarm will be triggered. 0 represents the
function is disabled.
5. Click Save.
6.11.9 Configure Screen Parameters
The device can connect to a text screen. You can set the display parameters on this page.
Steps
1. Click Maintenance and Management → Device to enter the device list.
2. Click to enter the remote configuration page.
3. Click System → Screen Configuration .
4. Set the screen parameters.
Note
For better performance, it is suggested to use the default parameters.
Screen Position
DS-K3B501S Series Swing Barrier User Manual
89
Summary of Contents for DS-K3B501S Series
Page 1: ...DS K3B501S Series Swing Barrier User Manual ...
Page 30: ...Entering Wiring Exiting Wiring DS K3B501S Series Swing Barrier User Manual 17 ...
Page 32: ...Figure 2 8 Fire Alarm Module Wiring DS K3B501S Series Swing Barrier User Manual 19 ...
Page 115: ...Figure F 2 Device Command DS K3B501S Series Swing Barrier User Manual 102 ...
Page 116: ...UD18744B ...