Note
• The cable bare part should be no more than 8 mm. It is suggested that you can immerse the
bare part into the liquid tin. If possible, wear an insulation cap at the end of the bare cable.
Make sure there’s no bare copper or cable after the wiring.
• The Terminal L and the Terminal N cannot be wired reversely. Do not wire the input and output
terminal reversely.
• To avoid people injury and device damage, when testing, the ground resistance of the
equipotential points should not be larger than 2 Ω
。
2.3 Wire Interconnecting Cable
You should use interconnecting cables to connect the master lane board and the slave lane board
for components communication.
The picture displayed below describes the cable hole's position on the pedestals.
Figure 2-3 Cable Hole of Interconnecting Cable
2.3.1 General Wiring
The picture displayed below describes the interconnecting cable's wiring diagram.
DS-K3B501S Series Swing Barrier User Manual
5
Summary of Contents for DS-K3B501S Series
Page 1: ...DS K3B501S Series Swing Barrier User Manual ...
Page 30: ...Entering Wiring Exiting Wiring DS K3B501S Series Swing Barrier User Manual 17 ...
Page 32: ...Figure 2 8 Fire Alarm Module Wiring DS K3B501S Series Swing Barrier User Manual 19 ...
Page 115: ...Figure F 2 Device Command DS K3B501S Series Swing Barrier User Manual 102 ...
Page 116: ...UD18744B ...