Other Settings
Set other parameters.
Steps
1. Click Configuration → Turnstile → Other Settings to enter the page.
2. Set Alarm Output Duration.
Note
The alarm output duration ranges from 0 s to 3599 s.
3. Set Temperature Unit.
4. Check to enable Do Not Open Barrier When Lane is Not Clear.
5. Drag the block or enter the value to adjust the light board brightness.
6. Set the alarm buzzer beeping duration, door closing delay time, intrusion duration, overstaying
duration and IR obstructed duration.
7. Check to enable Memory Mode at your actual needs.
Note
Multiple cards presenting for multiple person passing is allowable when enabling the memory
mode. When the passing person's number exceeds the card presenting number, or after the
latest person passing with no other person passing within the door open duration, the door will
close automatically.
8. Choose the control mode.
Soft Mode
The barrier will be closed after the person has passed through the barrier when there are
tailing, forced accessing, etc.
Guard Mode
The barrier will be closed immediately when there are tailgating, forced accessing, etc.
9. Set the fire input type.
10. Click to enable Motor Self-Test and choose the main lane or sub lane to start motor self-
testing.
11. Click Save.
9.6.13 Card Settings
Set Card Security
Click Configuration → Card Settings → Card Type to enter the settings page.
DS-K3B631TX Series Swing Barrier User Manual
80
Summary of Contents for DS-K3B631TX Series
Page 1: ...DS K3B631TX Series Swing Barrier User Manual ...
Page 23: ... The dimension is as follows DS K3B631TX Series Swing Barrier User Manual 9 ...
Page 35: ...Figure 5 7 Sub Access Control Board Terminal DS K3B631TX Series Swing Barrier User Manual 21 ...
Page 47: ...Figure 5 22 Remaining Closed DS K3B631TX Series Swing Barrier User Manual 33 ...
Page 174: ...UD30186B ...