Figure 2-5 Face Recognition Terminal Wiring
Note
• The supplied interconnecting cable length is 3.75 m. If you need a longer one, ask our technique
supports or sales and purchase 5.5 m interconnecting cables.
• The suggested inner diameter of the low voltage conduit is larger than 30 mm.
• If you want to bury both of the AC power cord and the low voltage cable at the entrance side,
the two cables should be in separated conduits to avoid interference.
• If more peripherals are required to connect, you should increase the conduit diameter or bury
another conduit for the external cable.
• The external AC power cord should be double-insulated.
• The suggested network cable should be CAT5e or the network cable has better performance.
And the suggested network cable length should be less than 100 m.
2.4 Terminal Description
The lane controller contains master lane controller and slave lane controller, which controls the IR
beams, motor, and other components' work.