Figure 2-3 Wire Face Recognition Terminal
Note
• The left pedestal and the middle pedestal should bury interconnecting cables for connecting
the face recognition terminal.
• The face recognition terminal installed on the left pedestal will gain power from the sub
switch, which should connect to high voltage.
• The supplied interconnecting cable length is 5.5 m.
• The suggested inner diameter of the low voltage conduit is larger than 30 mm.
• If you want to bury both of the AC power cord and the low voltage cable at the entrance, the
two cables should be in separated conduits to avoid interference.
• If more peripherals are required to connect, you should increase the conduit diameter or
bury another conduit for the external cables.
• The external AC power cord should be double-insulated.
• The network cable must be CAT5e or the network cable has better performance. And the
suggested network cable length should be less than 100 m.
DS-K3Y501SX Series Flap Barrier Quick Start Guide
5