background image

Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China

D Series Door Station

Diagram References

E N G L I S H

Appearance

1

Low Illumination Supplement Light

Camera

LCD Display Screen

1

2

3

4

5

6

Keypad

Call Button

Note: The appearance of the device vary according to different model. Refers to the actual device.

UD19918B

1

3

9

Call Center Button

7

Microphone

8

Card Reading Area

Loudspeaker

10

TAMPER

DS-KD8103-E6

2

1
2

3

4

9

10

5

7

8

6

RES 

GND 

W1 

W0 

BZ 

ERR

OK 

TAMP 

A

O2- 

A

O2+ 

A

O1- 

A

O1+ 

AIN4 

AIN3

AIN2 

AIN1 

NO1

C

OM1

NC1

NO2

C

OM2

NC2

GND

RES

SEN1 

BTN1 

SEN2 

BTN2 

GND 

485A+ 

485A-

GND

WIEGAND

12 VDC

GND

LOCK1

LOCK2

ALARM OUT

ALARM IN

ALARM IN

LAN

RESERVED

POWER

RS485

1

2

3

4

Installation

Before you begin:

Accessory

3

Terminal

2

1. Accessories that you need to prepare for installation: gang box and mounting template.

2. Make sure the power supply meet the power requirements of the door station (12 VDC, 1 A).

3. Make sure all the related equipment is power-off during the installation. 

4. Wire the cables before installation.

    The dimension of the gang box is: 404 mm(W) × 123 mm(H) × 47.5 mm(D).

    The installation hole should be larger than gang box. The suggested dimension of the installation hole 

is 404.5 

mm(W) × 123.5 mm(H) × 48 mm(D).

Flush Mounting

1. Drill an installation hole on the wall.

Note: 

The size of the hole should be larger than that of the gang box. The suggested dimension of the 

installation hole is 404.5 mm(W) × 123.5 mm(H) × 48 mm(D).

2. Insert the gang box into the hole and fix it with 4 PA4 screws. Make sure the edges of the gang box 

align to the wall. Route the cables of the door station through the cable hole.

3. Pull the door station downward and then push it towards the inside to make sure it fits the hole. 

4. Tighten the screws of the door station with the Allen wrench.

NC1/NC2:

 Door Lock Relay Output (NC)

NO1/NO2: Door Lock Relay Output (NO)

COM1/COM2: Common Interface

DC 12 V: Power Supply Input

AO1+/AO1- : Alarm Relay Output 1
AO2+/AO2- : Alarm Relay Output 2

AIN1/AIN2/AIN3/AIN4: Alarm Input

SEN1/SEN2

: Door Contact Detection Input/Door Contact

BTN1/BTN2

: Door Contact Detection Input/Exit Button

GND: Grounding

485A-: RS-485 Communication Terminal
485A+: RS-485 Communication Terminal

TAMP

Wiegand Card Reader TAMPER

OK: Card Reader Indicator Output (Valid)
ERR: Card Reader Indicator Output (Invaild)

BZ: Card Reader Buzzer Output
W0: Data Input Interface Wiegand Card Reader
W1: Data Input Interface Wiegand Card Reader
RES: Reserved

Note: Wiring description refers to the User Manual.

Call from Main/Sub Door Station

Call from Outer Door Station

Configuration

4

Activate Device

1. Power on the device to enter the activation page automatically.

2. Create a password and confirm it.

3. Press # to activate the door station.

Note: 

    Enter an 8 to 16 characters admin password.

    When entering the password, taking the numeric key 2 as example, press the numeric key 2 once, the text 

field shows “2”, and press it again in 1.5 s, the text field shows “a”, and press it again in 1.5 s, the text field 

shows “b”, and so on.

    Hold 0 to enter special characters.

    Press # to confirm the password.

    Press * to delete the password during entering.

You are required to activate the device first by setting a strong password for it before you can use the device.

1

Call Resident

The door station can work as main/sub door station, and outer door station, which correspond to different 

calling resident modes respectively.

Press number button to enter the calling page.

Enter the room No. and press call button again to call.

2

Call Center

3

Press number button to enter the calling page.

Enter

Building No. + # + Unit No. + # + Room No.

 and press call button to call resident.

Press number button to enter the calling page.

Press center button to call. Press * to cancel during calling management center.

Unlock by Entering Password

Unlock by Presenting Card

The device support unlock the door by presenting card, entering password, and fingerprint. Here 

takes unlock by entering password and unlock by presenting card for example.

Note: You should create the password and add the card to the device first.

    Common Password

Press number button, ente

r

# + room No. + pa #

 to unlock the door.

    Public Password

Note: Create the public password via iVMS-4200 Client Software remotely first.

Press number button, enter

# + public pa #

】 

to unlock the door.

Present the card on the card reading area to unlock the door.

Unlock Door

4

       Refer to Video Intercom D Series Door Station User Manual (scan the QR code) for details.