2
DS-KV61X3-(W)PE1
Video Intercom Villa Door Sta on
UD20195B-B
Microphone
2
Indicator
3
Bu on
4
Card Reading Area
5
Loudspeaker
6
Terminals
7
Debugging Port
8
Note: The debugging port is used for debugging only.
Terminal and Wiring
2
Installa on Accessory
3
ENGLISH
Diagram References
Appearance
1
Surface Moun ng without Protec ve Shield
1. S ck the moun ng template on the wall. Drill screw holes according to the moun ng
template. Remove the template from the wall.
2. Secure the moun ng plate on the wall with 4 supplied screws according to the screw
holes.
3. Install the villa door sta on to the moun ng plate. Fix the device on the moun ng
plate with the set screw.
Surface Moun ng with Protec ve Shield
Make sure all related equipments are power-off during the installa on.
Tools that you need to prepare for installa on:
Drill (ø2.846) and gradienter.
Purchase the protec ve shield before installa on.
Before You Start
1. S ck the moun ng template on the wall. Drill the screw holes according to the
moun ng template. Remove the template from the wall.
2. Align the protec ve shield with the moun ng template.
3. Secure the moun ng plate and protec ve shield on the wall with 4 supplied screws
according to the screw holes.
4. Install the villa door sta on to the moun ng plate. Fix the device on the moun ng
plate with the set screw.
1
1
Configura on via Web
5
You are required to ac vate the device first by se ngs a strong password before you
can use the device.
Ac vate Device via Web
1
Access to the Device by Web Browsers
2
1. In the browser address bar, enter the IP address of the device, and press the Enter
key to enter the login page.
2. Enter the user name and password and click Login.
Refers to Video Intercom Villa Door Sta on User Manual (scan the QR code) for details.
1
TAMPER
9
4
2
3
4
5
6
7
8
9
10
11
12
Exit Button
TO
EXIT
2
1
3
Screws
Screw
Villa Door Station
Mounting Plate
Mounting Template
Wall
1
3
4
2
Screws
Screws
Screw
Villa Door Station
Mounting Plate
Protective Shield
Mounting Template
Wall
The recommended distance from the ground level is 1.40
adjustable depends on the height of body.
102023104
Hole
1
Hole
2
Hole
1
Hole
1
Hole
1
102.58
1.18
Unit : mm
6.2
39.24
3.45
3
Orange
RS-485+
Yellow
RS-485-
Red
12 VDC
Black
GND
White
AIN1
White
AIN2
White
AIN3
White
AIN4
Yellow
NC
Green
COM
Blue
NO
Black
GND
Black
GND
PRESS
Power
Input
Reserved
1
2
Surface
Moun ng
without Protec ve Shield
Surface
Moun ng
with Protec ve Shield
DS-KV6103-PE1
DS-KV6113-WPE1
1
Camera
Set Screw
10
TF Card Slot
11
Network Interface
12
Indicator Descrip on
Unlock: Green
Call: Orange
Communicate: White
NC: Door Lock Relay Output (NC)
NO: Door Lock Relay Output (NO)
COM: Common Interface
AIN1: For the access of Door Contact
AIN3: For the access of Exit Bu on
AIN2&AIN4: Reserved
485-: RS-485 Interface (Reserved)
485+: RS-485 Interface (Reserved)
12 VDC IN: Power Supply Input
GND: Grounding
Moun ng Template
2
1
Moun ng Plate
Note: The dimension of the moun ng plate is 102.58 mm × 39.24 mm × 6.2 mm.
Installa on
4
Note: Video intercom villa door sta on supports surface moun ng.
Default parameters of door sta on are as follows:
Default IP Address: 192.0.0.65.
Default Port No.:8000.
Default User Name: admin
1. Power on the device, and connect the device to the network.
2. Enter the IP address into the address bar of the web browser, and click Enter to enter
the ac va on page.
Note: The computer and the device should belongs to the same subnet.
3. Create and enter a password into the password field.
4. Confirm the password.
5. Click OK to ac vate the device.
Note: When the device is not ac vated, the basic opera on and remote configura on of device cannot be
performed.
Communicate with Indoor Sta on
3
1. Click Se ngs -> Intercom -> Press Bu on to Call to enter the se ngs page.
2. Set the parameters.
- Edit call No. for every bu on.
- Check Call Management Center to set the bu on calling center.
Note: If you check Call Management Center and set the call No. as well, call management center has
higher privilege than call No.
3. Press bu on to call indoor sta on.
Issue Card
4
1. Click Se ngs -> Access Control and Elevator Control to enter the se ngs page.
2. Click Issue Card. Present the card on the card reading area.
3. When issuing finished, the windows pop up on the se ngs page.
Note:
Only Mifare card supported, and Mifare card with non-standard shape is recommended.
Up to 10000 cards can be issued and managed by V series door sta on. A voice prompt (No more cards
can be issued.) can be heard when the issued card amount exceeds the upper limit.
Unlock Door
5
A er issuing cards, you can unlock the door by presen ng the issued cards.
Model
Received frequency
Transmi ed frequency
Bandwidth
Frequency power
802.11b:16dBm +/- 1.5dBm
802.11g:15dBm +/- 1.5dBm
802.11n(ht20):14dBm +/- 1.5dBm
802.11n(ht40):12dBm +/- 1.5dBm
DS-KV6113-
WPE1
2.4
to 2.4835GHz
2.4 to 2.4835GHz
20 to 40MHz
Industry Canada ICES-003 Compliance
This device meets the CAN ICES-3 (B)/NMB-3(B) standards requirements.
For RED-Direc ve 2014/53/EU
The frequency, mode and the maximum transmi ed power in EU are listed below:
The simplified declaration of conformity
Hereby, Hangzhou Hikvision Digital Technology Co., Ltd. ("Hikvision") declares that
the DS-KV6113-WPE1 device complies with the requirements of Directive 2014/53 / EU of
the European Parliament and of the Council of April 16, 2014 on the harmonization of
the laws of the Member States relating to making radio equipment available on the
market and repealing Directive 1999/5 / EC. The full text of the declaration of
conformity is available at the Hikvision website