8

Operation

Keypad Status

Operation Interval

Keypad Lock

Sleep Status

Working  Status

Enrollment Status

Free Status

The keypad will enter the sleep status 

while meeting the following conditions:

No RF data transmission

No key operation for more than 10 s

No keypad tampering alarm

No polling

No beeping

No LED indication

The keypad will enter the sleep status while 

meeting the following conditions:

RF data transmission

key operation

keypad tampering alarm

polling

Beeping

LED indication

While the keypad is enrolled to a control 

panel, it enters the enrollment status.

Only if the keypad is enrolled, the key 

operation and status indication take 

effects. 

There is no area related to the keypad.

The key and back light do not works.

The interval between the operations (successful or failed) should be more than 3 s.

The continuous operation of the key should be in 10 s.

The Key pad will be locked after 3 to 5 failure authentication attempts.You can set the lock time on the web client of 

the control panel

Arming Process

Pre-delay

Indication:

The arming LED turns flashing blue

Fault Checking

Indication:

The arming LED turns flashing orange

Exit Delay

Indication:

Arming LED turns flashing blue, and the buzzer indicates exit delay.

Arm Directly

Press the Arm key to arm the device.

Indication:

Armed: arming LED solid blue for 5 s. Buzzer beeps twice.

Arming failed: Buzzer beeps three time.

Disarm

Press the Disarm key to disarm the device.

Indication:

Armed: Buzzer beeps twice.

Arming failed: Buzzer beeps three time.

No Instant Operation

The count down is finished.

Indication:

Armed: arming LED solid blue for 5 s. Buzzer beeps twice.

Arming failed: Buzzer beeps three time.

  

Confirm the operation by press the Arm key

4

Summary of Contents for DS-PK1-E-WA

Page 1: ...efore with the applicable harmonized European standards listed under the EMC Directive 2014 30 EU the RE Directive 2014 53 EU the RoHS Directive 2011 65 EU replacement of a battery with an incorrect type that can defeat a safeguard for example in the case of some lithium battery types disposal of a battery into fire or a hot oven or mechanically crushing or cutting of a battery that can result in a...

Page 2: ...the power switch of the peripheral to on and it will be automatically enrolled to the control panel 1 Remove the screw on the bottom of the keypad 2 Disassemble the keypad and remove the rear panel 3 Power on the security control panel 4 Log in the Hik Connect APP and tap the icon Scan the QR code or input the control panel serial No to add the control panel 5 Enroll the peripheral locally with OR...

Page 3: ...three times Clear alarm User Password Hold Disarm Fire Hold 1 Fire Alarm for 3 s The Buzzer will beep three times for failure operation PA Hold 2 Panic Alarm for 3 s The Buzzer will beep three times for failure operation Medical Hold 3 Medical for 3 s The Buzzer will beep three times for failure operation Duress Duress Code disarm You can set the duress code on the web client of the control panel ...

Page 4: ...en the operations successful or failed should be more than 3 s The continuous operation of the key should be in 10 s The Key pad will be locked after 3 to 5 failure authentication attempts You can set the lock time on the web client of the control panel Arming Process Pre delay Indication The arming LED turns flashing blue Fault Checking Indication The arming LED turns flashing orange Exit Delay Ind...

Reviews: