DS-PR1-60 User Manual
UM DS-PR1-60 090920NA
27
Chapter 5 Camera Linkage Settings
The radar can work with cameras such as speed domes and box cameras for target tracking and video
recording.
5.1
Set Speed Dome Initial Position
Set the initial position of the speed dome to ensure the tracking accuracy.
1.
Select a reference object about 50 m away from the speed dome. On the reference object, select a
reference point whose altitude is the same as the speed dome’s.
Figure 5-1 Reference Point Position
2.
Enter the IP address of the speed dome in the Web browser to enter the Web client. Adjust the PTZ
buttons to make sure that the reference point is displayed in the live view window. Click
to enable 3D
location, click the reference point and the point will be in the middle of the frame.
If the speed dome is installed tilted, after you click
, you may find the reference point is
above the center of the frame or outside the frame. In this case, adjust the maximum
elevation angle of the speed dome. For detailed adjustment method, refer to
How to Solve
the Problem that No Reference Point is on the Frame While Setting the Speed Dome Initial
Position?
If the maximum elevation angle of the speed dome is adjusted, the reference point needs to
be adjusted to the center of the frame again.
PTZ
: Pan /tilt /zoom.
3.
Enter the
Configuration
→
PTZ
→
Initial Position
page, and click
Set
to set the initial position.
Summary of Contents for DS-PR1-60
Page 1: ...DS PR1 60 Security Radar User Manual...
Page 42: ...DS PR1 60 User Manual UM DS PR1 60 090920NA 42...
Page 69: ...DS PR1 60 User Manual UM DS PR1 60 090920NA 69...
Page 70: ...DS PR1 60 User Manual UM DS PR1 60 090920NA 70...
Page 71: ...DS PR1 60 User Manual UM DS PR1 60 090920NA 71 UD13649B...