3.2.1 Selecting Pattern
Three patterns are selectable: PATTERN_ALL (pattern 1), PATTERN_I_O (pattern 2) and
PATTERN_SERIAL (pattern 3).
Step 1
Check the checkbox of Show to enable the settings.
Step 2
Select a pattern from the drop-down list.
PATTERN_ALL: trigger the input by I/O or serial port enabling as user demand.
PATTERN_I_O: trigger input by I/O only.
PATTERN_SERIAL: trigger input by serial port enabling command only.
Step 3
Click the SendCommand to complete the settings.
Figure 3-2
Select Pattern
3.2.2 Triggering by I/O
Task1: Input Settings
The input settings must be configured when the external signal (e.g., photoelectric sensor) is used
for triggering the input port.
Figure 3-3
Input Triggering Pattern
Step 1
Check the checkbox of Show to enable the settings.
Step 2
Select the SSET_STATU mode to configure the parameters.
1)
Check the checkbox of port 1-4 as demand.
2)
Select the IO_INPUT from the drop-down list.
3)
Check the checkbox of output ports.
4)
Select the ACTION_START and configure it to EDGE_RISING or EDGE_FALLING triggering
mode.
5)
Set the delay time (ms) and select the NOTICE_ON or NOTICE_SEND to send the notice or
not.
6)
Click the SendCommand to complete the settings.