Vision Box User Manual
15
Step 3
Repeat the sub steps 1) to 3) of Step 2, and select the ACTION_END and configure it to
EDGE_RISING or EDGE_FALLING triggering mode. And repeat the sub steps 5) to 6) of Step 2
to complete the settings.
Task2: Output Settings
The PWM output and pulse output can be configured. The PWM output setting is taken as the
example in the following instructions.
Figure 3-4
PWM Output Settings
Step 1
Select the SSET_STATU mode to configure the parameters.
Step 2
Check the checkbox of port 1-4 as demand.
Step 3
Select the IO_PWM_OUT from the drop-down list.
Step 4
Set the parameters of pulse width (ms), cycle time (ms), and duration (ms).
You can enter Max in the duration to set continuous outputting.
Step 5
Click the SendCommand to complete the settings.
3.2.3 Triggering by Serial Port
Purpose
The serial port parameters must be configured when you use it to trigger the input. The pulse
output setting is taken as the example in the following instructions.
Figure 3-5
Pulse Output Settings
Step 1
Set the pulse parameters.
1)
Select the SSET_STATU mode to configure the parameters.
2)
Check the checkbox of port 1-4 as demand.
3)
Select the IO_PULSE_OUT from the drop-down list.
4)
Select the LEVEL_HIGHT, and set the parameters of pulse number, duration (ms) and
pulse interval (ms).
Summary of Contents for MV-VB2100-032G
Page 1: ...Vision Box User Manual UD04763B...
Page 22: ...Vision Box User Manual 21...