background image

Vision Box User Manual 

Regulatory Information 

FCC Information 

Please  take  attention  that  changes  or  modification  not  expressly  approved  by  the  party 

responsible for compliance could void the user’s authority to operate the equipment. 
FCC compliance: This equipment has been tested and found to comply with the limits for a Class A 
digital  device,  pursuant  to  part  15  of  the  FCC  Rules.  These  limits  are  designed  to  provide 
reasonable  protection  against  harmful  interference  when  the  equipment  is  operated  in  a 
commercial environment. This equipment generates, uses, and can radiate radio frequency energy 

and,  if  not  installed  and  used  in  accordance  with  the  instruction  manual,  may  cause  harmful 
interference to radio communications. Operation of this equipment in a residential area is likely to 
cause harmful interference in which case the user will be required to correct the interference at 
his own expense. 

FCC Conditions 

This  device  complies  with  part  15  of  the  FCC  Rules.  Operation  is  subject  to  the  following  two 
conditions: 

1. This device may not cause harmful interference. 

2.  This  device  must  accept  any  interference  received,  including  interference  that  may  cause 
undesired operation. 

EU Conformity Statement 

This product and - if applicable - the supplied accessories too are marked with "CE" and 

comply  therefore  with  the  applicable  harmonized  European  standards  listed  under  the 

EMC Directive 2014/30/EU, the LVD Directive 2014/35/EU, the RoHS Directive 2011/65/EU.   

2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of 

as  unsorted  municipal  waste  in  the  European  Union.  For  proper  recycling,  return  this 
product  to  your  local  supplier  upon  the  purchase  of  equivalent  new  equipment,  or 

dispose of it at designated collection points. For more information see: 

www.recyclethis.info

 

2006/66/EC (battery directive): This product contains a battery that cannot be disposed 

of as unsorted municipal waste in the European Union. See the product documentation 

for  specific  battery  information.  The  battery  is  marked  with  this  symbol,  which  may 

include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return 
the  battery  to  your  supplier  or  to  a  designated  collection  point.  For  more  information  see: 

www.recyclethis.info 

Industry Canada ICES-003 Compliance 

This device meets the CAN ICES-3 (A)/NMB-3(A) standards requirements.   

Summary of Contents for MV-VB2100-032G

Page 1: ...Vision Box User Manual UD04763B...

Page 2: ...11 2 4 2 OutputConnections 11 Chapter 3 Operation of I O and Demo 13 3 1 Input Output Pattern 13 3 2 Operation of Demo 13 3 2 1 Selecting Pattern 14 3 2 2 Triggering by I O 14 3 2 3 Triggering by Ser...

Page 3: ...below are the properties of their respective owners Legal Disclaimer TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW THE PRODUCT DESCRIBED WITH ITS HARDWARE SOFTWARE AND FIRMWARE IS PROVIDED AS IS...

Page 4: ...This device must accept any interference received including interference that may cause undesired operation EU Conformity Statement This product and if applicable the supplied accessories too are mark...

Page 5: ...as follows Symbol Description Provides additional information to emphasize or supplement important points of the main text Indicates a potentially hazardous situation which if not avoided could resul...

Page 6: ...Tips Before connecting and operating your device please be advised of the following tips Ensure unit is installed in a well ventilated dust free environment Unit is designed for indoor use only Keep...

Page 7: ...test etc 1 2 Features Onboard Intel E3845 SOC 1 91GHz CPU providing 200 CPU and 350 GPU performance more than the last generation D525 D2550 processor Adoption of Gen7 GPU greatly enhances the image p...

Page 8: ...terface 1 USB 3 0 host interface 1 composite interface USB3 0 client USB2 0 host 2 USB 2 0 host interface External interfaces 1 RS 485 half duplex 1 RS 232 GPIO 4 inputs 4 outputs Audio HAD Stereo Lin...

Page 9: ...s and Connections 2 1 Dimensions Refer to the following figure for the outline and dimensions of the Vision Box 134 8 7 2 91 45 50 80 4 M3 4 Figure 2 1 Outline and Dimensions 2 2 Installation Use four...

Page 10: ...RS232 USB USB2 0 RS485 LAN PWR HDD HDMI1 USB2 0 HDMI2 G 4 3 2 1 G C 4 3 2 1 1 2 3 4 G 1 2 3 4 C G DI DO HDMI GPIO USB2 0 1 2 3 4 5 6 7 8 9 10 13 11 12 Figure 2 3 Indicators and Interfaces on the Panel...

Page 11: ...read from or written to HDD 6 GPIO 4 GPIO input and 4 GPIO output connectors 7 Power Switch for turning on off the device 8 USB 3 0 interface 1 USB 3 0 host interface 1 composite interface USB3 0 clie...

Page 12: ...ical isolation input GND 6 DO1 Optical isolation output 1 7 DO2 Optical isolation output 2 8 DO3 Optical isolation output 3 9 DO4 Optical isolation output 4 10 COMMON Common 11 OUT_GND Optical isolati...

Page 13: ...onnection Mode A Connection Mode B When the output is used as the signal you need to add a pull up resistor 12V 1 4k 24V 2 8k between the Common and Output to form a level signal Refer to the followin...

Page 14: ...wing three configuration patterns are selectable Pattern 1 All triggering input by I O or serial port triggering is configurable Pattern 2 triggering input by I O is configurable only Pattern 3 trigge...

Page 15: ...3 2 Select Pattern 3 2 2 Triggering by I O Task1 Input Settings The input settings must be configured when the external signal e g photoelectric sensor is used for triggering the input port Figure 3 3...

Page 16: ..._PWM_OUT from the drop down list Step 4 Set the parameters of pulse width ms cycle time ms and duration ms You can enter Max in the duration to set continuous outputting Step 5 Click the SendCommand t...

Page 17: ...complete the settings 3 2 4 Configuring Serial Port Property In the original operating system the default port used by GPIO is Com2 with the baud rate of 115200 8 data bits and 1 stop bit Hardware of...

Page 18: ...IRQ Original Serial Port No Correspond Function IRQ Information COM1 RS232 0x00000004 04 COM2 GPIO 0x0000000A 10 COM3 RS485 0x00000003 03 COM4 NULL 0x0000000B 11 Click Advanced in Port Settings page...

Page 19: ...ox User Manual 18 Figure 3 8 Hardware modification window correspond to serial port The Com1 of the Vision Box corresponds to the RS 232 the Com3 to RS 485 and the Com4 is null Figure 3 9 Serial Port...

Page 20: ...olution is supported 4 2 Remote Access The Vision Box is installed with the MVWhere client software for device access to the LAN Use the MVWhere client software to find the IP address of the controlle...

Page 21: ...1 Start up the device and press the DELETE key to enter the BIOS settings page Step 2 Enter the Advanced CSM Configuration menu and set the Boot option filer to Legacy only Step 3 Enter the BOOT menu...

Page 22: ...Vision Box User Manual 21...

Reviews: