A6 version
Channel 2---regular operation in the practical application, Eg:
Press the password of channel 2
123456
Press button B
Button B
Less than 4s, then re-press button B
Can transmit signal
More than 4s, then re-press button B
Can’t transmit signal
VI. Reset Password
If password is lost, then need to open the lock with the key, take apart the battery. Keep pressing any button for 2s,
meanwhile, remount the battery then release button. Led “B, 2, 1, A” light on at the same time and goes off one by one,
then password will back to the initial setup as “000000”. Initial password can be changed into others according to the
above operation (ATTN: Keypad and receiver or controller need to rematch again after reset the password).
VII. Low Voltage Alarm
If the battery voltage is lower than 2.4V, the indicator light “1,2” will turn on together when pressing
number”0-9” (Remind user to replace with new battery).
VIII. Model list
Model
Frequency
Color
After button A and B learning into multichannel
K5000
433.92MHz
White
A controls multichannel 1, B controls multichannel 2
K5010
318 MHz
White
A controls multichannel 1, B controls multichannel 2
K5001
433.92MHz
Black
A controls multichannel 1, B controls multichannel 2
K5011
318 MHz
Black
A controls multichannel 1, B controls multichannel 2
IX. To learn a receiver
How to learn keypad channel 1 to a receiver ?
Press the learning button on receiver and the LED light turns red, and press the button A on keypad twice after
enter the password for keypad channel 1. LED light on receiver will be flashing and turns Green. Learning
process is finished.
It is the same for channel 2.
X. Installation
a.
It’s better to test the functionality of product and effective working range before installation
b.
The range of remote control may reduce 25%-30% if the battery is low power.
c. The product is with dust cover, keep it closed after use the keypad and open it before pressing
password to operate.
10.1 Position
Besides Keeping away from other receiver, do not install the product near nor connect metal object,
otherwise the signal will be shielded. It can be installed outside according to user’s needs because of the IP54
protection.
info@stedaparts.nl
www.stedaparts.nl