NOTES:
* STUB-UP AREA
** RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS
z
ENDS ADD APPROXIMATELY 1 INCH TO CASE HEIGHT
z
WIRING-TO-THE-TOP- ADDS APPROXIMATELY 1 INCH TO CASE HEIGHT
z
A 2" MINIMUM AIR GAP IS REQUIRED BETWEEN THE REAR OF THE CASE AND A WALL
z
SUCTION LINE (ALL LENGTHS) 1/2"
z
LIQUID LINE (ALL LENGTHS) - 3/8", LIQUID LINE w/ HOT GAS DEFROST (ALL LENGTHS) - 1/2"
z
AVAILABLE SHELF SIZES: WIRE SHELVES 16", 18", 20" & 22"
SOLID SHELVES 18", 20" & 22"
(TOP SHELF MUST BE 20" OR SHORTER. RECOMMENDED CONFIGURATION IS 20"
SHELF AND 4 22" SHELVES BELOW TOP SHELF)
PIPING-TO-TOP
(OPTIONAL)
COIL
PLENUM
23 1/4 in
[59.1 cm]
6 13/16 in [17.3 cm]*
35 3/8 in [89.8 cm]
5 1/8 in
[13.1 cm]
16 1/4 in
[41.3 cm]
8 in
[20.3 cm]
24 3/16 in [61.4 cm]
31 7/8 in [81.0 cm]
34 5/8 in [88.0 cm]
7 1/2 in
[19.1 cm]
1/2 BUMPER OPTION
87 1/16 in
[221.1 cm]
85 1/16 in
[216.0 cm]
63 in
[160.0 cm]
66 3/8 in
[168.6 cm]
(Door Height)
68 in
[172.7 cm]
(Frame Height)
C
L
JUNCTION BOX
(STANDARD)
WIRING-TO-TOP
(OPTIONAL)
1 1/2" PVC DRAIN
CONNECTION
REFRIGERATION
FRONT OF CASE
10 in
[25.4 cm]
8 in [20.3 cm]
27 9/16 in
[70.0 cm]
**
23 1/4 in
[59.1 cm]
26 7/8 in
[68.3 cm]
1 1/2 in [3.8 cm]
{END}
8 11/16 in [22.1 cm]
24 3/16 in
[61.4 cm]
31 7/8 in
[81.0 cm]
27 5/16 in
[69.4 cm]
REAR REFRIGERATION
(12 1/4" off of floor)
4 in
[10.2 cm]
3 3/8 in [8.6 cm]
12 3/4 in [32.4 cm]
60 in [152.4 cm] {2 Door}
90 in [228.6 cm] {3 Door}
120 in [304.8 cm] {4 Door}
150 in [381.0 cm] {5 Door}
35 3/8 in
[89.8 cm]
ELECTRICAL
16 1/16 in [40.8 cm]
18 9/16 in [47.1 cm]
MODEL
ONRBH
Amp plate &
Serial Plate
location
Summary of Contents for ONRB
Page 2: ......
Page 4: ......
Page 6: ...2...
Page 24: ...20 WIRING DIAGRAMS 15 16 ORB ORBH ONRB ONRBH 2 DOOR...
Page 25: ...21 WIRING DIAGRAMS 15 16 ORB ORBH ONRB ONRBH 3 DOOR 8...
Page 26: ...22 WIRING DIAGRAMS 15 16 ORB ORBH ONRB ONRBH 4 DOOR 12...
Page 29: ...25 WIRING DIAGRAMS GFI...
Page 42: ...38 NOTES...