UPL-NRG
E
NERGY
D
ATA
Electrical Data
Defrost Controls
1
NOTE: “- - -” not an option on this case model.
2 BTUH/ft
notes:
- Listed BTUH/ft indicate parallel operation. Conventional ratings may be approximated by multiplying listed rating by 1.13.
- Add 132 BTUH/ft when aftermarket merchandising accessories are utilized to determine the total BTUH load.
3
Average discharge air velocity at peak of defrost.
Guidelines & Control Settings
Model
2
BTUH/ft
Superheat
Set Point @ Bulb
(oF)
Evaporator
(oF)
Discharge
Air
(oF)
Return
Air
(oF)
Discharge
3
Air
Velocity
(FPM)
UPL-NRG
500
6-8
26
30
40
250
Model
Defrosts
per Day
Electric Defrost
Timed-Off Defrost
Hot Gas Defrost
Reverse Air Defrost
Fail-Safe
(min)
Termination
Temp (oF)
Fail-Safe
(min)
Termination
Temp (oF)
Fail-Safe
(min)
Termination
Temp (oF)
Fail-Safe
(min)
Termination
Temp (oF)
UPL-NRG
6
- - -
- - -
45
42
- - -
- - -
- - -
- - -
Model
Fans
per
Case
High Effi ciency
Fans
Anti-Condensate
Heaters
Defrost Heaters
120 Volts
120 Volts
208 Volts
240 Volts
Amps
Watts
Amps
Watts
Amps
Watts
Amps
Watts
UPL-NRG
8’
2
0.17
20
- - -
1
- - -
- - -
- - -
- - -
- - -
2