45
Chapter 3 Installation
|
Hillstone
Hillstone SG-6000 X-Series Hardware Reference Guide
9.
Reinstall all removed hardware components back to the proper locations. See
Note
: Before powering on the device, all empty slots should be covered with blank
plates.
Installing Expansion Modules
This section describes how to install the expansion modules which are not pre-
installed at the factory.
Installing Expansion Modules of SG-6000-X10800
The device
requires at least one SCM, one SSM, one IOM and one SWM. Additional
expansion modules are added according to your needs.
This part includes the following sections:
Tools required
Installing an SCM/SWM
Installing an SSM/QSM/IOM/Bypass
Tools Required
The following tools are required to install an expansion module:
Cross screwdriver
ESD wrist strap
Installing an SCM/SWM
SG-6000-X10800
supports up to two SCMs and two SWMs. SCM is located in the
slot SCM0 and SCM1 of the back panel, and SWM is located in the slot SWM0 and
SWM1 of the back panel.
The following takes SCM as an example to introduce how to install an SCM or
SWM. To install an SCM, take the following steps:
1.
Wear an electrostatic discharge (ESD) strap around your bare wrist and connect
the strap to an ESD point on the chassis. See
2.
Take SCM out from its antistatic bag.
3.
Identify the slot of SCM.
4.
If the slot is covered with a blank plate, loose its screws with a cross
screwdriver and remove the plate, see
5.
Position the SCM so that its front side faces you. Make sure that the lever is on
the downside and the SCM module is plain with the outside edge of the