Traction Microswitch
. The micro is located inside the accelerator pedal. When the accelerator pedal
is pressed and the micro is closed, the traction card is enabled (as long as the deadman micro is pressed).
Vacuum motor Microswitch (Base)
. The micro is on the squeegee lifting lever. With lowered squeegee
lever and closed micro, when the traction pedal is pressed, the suction motor is activated.
Brush motor Microswitch (Base)
. The micro is on the brush deck lifting lever. With lowered brush
deck lever and closed micro, when the traction pedal is pressed, the brush motor is activated.