4.3
Drying System
•
Put the machine in safe conditions.
•
Open the front Carter and remove
the solution tank and the
recovery
tank
(see fig.
.
•
Remove the hoses cover carter by
unscrewing the fixing screws
(see fig.
.
•
Remove the
suction hoses body
by
loosening the screws. Together with
the body will extract also the
suc-
tion hose
(see fig.
.
•
Place the machine vertically and re-
lease the squeegee by rotating and
pulling the side knobs
(see fig.
.
•
Free the
squeegee body
from the
squeegee holder by releasing the fix-
ing knobs
(see fig.
) (see fig.
.
•
Remove
the
wheels
to
remove
squeegee support
(see fig.
) (see
section
at page
.
•
Open the output air filter compart-
ment and extract the filters
(see fig.
.
•
Unscrew the screws fixing the suc-
tion motor carter and remove it to-
gether with the air duct.
•
Pull out the
suction motor
, discon-
nect the connectors and remove the
rubber cap.
4.3.0-14
4.3.0-15
4.3.0-16
4.3.0-17
4.3.0-18
4.3.0-19
4.3.0-20
4.3.0-21
21