VIEWING THE LIST OF ALARMS
To view the list of alarms that have been active on the machine, proceed as follows:
1. With the machine on, press the menu button (1) on the working screen (
Fig.1
).
2. Press the setting (2) (
Fig.2
).
3. In the “MAIN MENU” screen, select the “MONITOR” option (3) on the left-hand side of the screen
(
Fig.3
).
N.B.
: when an option is selected from the list, this is highlighted.
OFFICE
0000.00
100%
0000.00
100%
ECO mode
1
2
1
2
3. In the “MAIN MENU” screen, select the “MONITOR” option (3) on the left-hand side of the screen
(
Fig.3
).
N.B.
: when an option is selected from the list, this is highlighted.
4. As soon as the “MONITOR” option is selected, the machine diagnostics screen will appear on the
display (
Fig.4
).
5. Select which machine function you want to perform the diagnosis on, choosing one of the options
displayed on the left-hand side of the screen (
Fig.4
).
N.B.
: the machine functions are divided as follows:
•
General
•
Brush
•
Pump
•
Vacuum
•
Traction
6. As soon as one of the functions is selected, the information relating to the devices for this
function appears on the right of the screen (
Fig.4
).
The table below provides a list of the variables that can be viewed:
UNIT
VARIABLE
U/M
DESCRIPTION
General
Battery voltage
V
Battery voltage
General
Solution empty switch
Solution tank empty float
General
Recovery empty switch
Recovery tank empty float
General
Reverse button
Reverse button
General
Power button
Power button
Brush
Brush current
A
Brush head brush current
Brush
Actuator Base
Brush head actuator
Brush
Heatsink Temp.
°C
Functions stage temperature
Pump
Flow rate
%
Water flow rate percentage
Pump
ELV base
Brush head solenoid valve
Vacuum
Current
A
Vacuum cleaner current
Vacuum
Voltage
V
Vacuum cleaner voltage
Vacuum
Actuator
Squeegee actuator
Vacuum
Heatsink Temp.
°C
Functions stage temperature
Traction
Voltage
V
Traction motor voltage
Traction
Current
A
Traction motor current
Traction
Overload level
%
Current limit status
Traction
Heatsink Temp.
°C
Traction stage temperature
Traction
Handle POT ref.
V
Gear potentiometer reference voltage
Traction
Handle En.
Dead man's lever pressed
7. To return to the program zone menu, press the “BACK” key.
8. To return to the main menu, press the “EXIT” key.
9. To return to the work screen, press the “EXIT” key.
Reset
Menu principale
Lingua
Contaore
Programmazione Zone
Parametri
Monitor
Allarmi
Esci
VISUALIZZATO
TOTALE PARZIALE
Chiave
0000.00 0000.00
Trazione
0000.00 0000.00
Spazzole
0000.00 0000.00
Aspirazione
0000.00 0000.00
Chiave
Monitor
General
Brush
Pump
Vacuum
Traction
Esci
Valore 1
100
Valore 2
23.5
Valore 3
Valore 4
A
V
OFF
ON
3
4
3
4
4. As soon as the “ALARMS” option is selected, the machine diagnostics screen will appear on the
display (
Fig.4
).
5. To return to the work screen, press the “EXIT” key.
Reset
Menu principale
Lingua
Contaore
Programmazione Zone
Parametri
Monitor
Allarmi
Esci
VISUALIZZATO
TOTALE PARZIALE
Chiave
0000.00 0000.00
Trazione
0000.00 0000.00
Spazzole
0000.00 0000.00
Aspirazione
0000.00 0000.00
Chiave
?
Reset
Menu principale
COUNT
Lingua
Contaore
Programmazione Zone
Parametri
Monitor
Allarmi
Esci
Allarme 1
000
0000.00
Allarme 2
000
0000.00
Allarme 3
000
0000.00
Allarme 4
000
0000.00
HOUR METER
3
4
3
4
ALARM
NUMBER
DESCRIPTION
AL_1: General
Memory Error
AL_2: General
Issue with Key
AL_10: General
Enter Tag
AL_11: General
Invalid Tag
AL_13: General
Switch off
AL_42: Function
Power Board Damaged
AL_43: Function
Main Fuse Faulty
AL_44: Function
Main Contactor Faulty
AL_45: Function
Main Contactor Faulty- CC
AL_60: Function
Timeout Actuator 1
AL_61: Function
Amperometric Actuator 1
AL_62: Function
Overcurrent Actuator 1
AL_63: Function
Limit Switch Incorrect Actuator 1
AL_64: Function
Timeout Actuator 2
AL_65: Function
Amperometric Actuator 2
AL_66: Function
Overcurrent Actuator 2
AL_67: Function
Limit Switch Incorrect Actuator 2
AL_68: Function
Timeout Actuator 3
AL_69: Function
Amperometric Actuator 3
AL_70: Traction
Overcurrent Actuator 3
AL_71: Traction
Limit Switch Incorrect Actuator 3
AL_80: Traction
Wrongconfig
AL_81: Traction
Watch dog
AL_82: Traction
EEPROM NOT OK
AL_83: Traction
LogicFailure #3
AL_84: Traction
LogicFailure #2
AL_85: Traction
LogicFailure #1
AL_86: Traction
VMN Low
AL_87: Traction
VMN High
AL_88: Traction
AUX Output KO (electric brake)
AL_89: Traction
Contactorclosed
AL_90: Traction
Contactor open
AL_91: Traction
I=0 ever
AL_92: Traction
STBY | High
AL_93: Traction
Capacitorcharge
AL_94: Traction
High temperature
AL_95: Traction
Motor temperature
AL_96: Traction
CAN Bus KO
AL_97: Traction
Encoder error
LOCK ALARMS
The alarms listed in the table below can be reset only be switching the machine off. They can entail the
immediate stopping of the entire machine or a part of it.
41