4.2.1-12
4.2.1-13
4.2.1-14
4.2.1-15
• Put the Brush Deck to let the Motor
Head touch the floor (or a table).
• Unscrew the Coupling Flange rotat-
ing it in the same direction as the
brush in standard working condi-
tions
(see fig.
.
• Remove the spacer
(see fig.
.
• Proceed at reverse to refit the part.
Note:
Before to refit the part lubricate
the thread in order to prevent blockings
because of dirt or oxide.
4.2.2-16
4.2.2-17
4.2.2-18
4.2.3
Brush Motor - Disc
• Put the machine in safe conditions.
• Disassemble the Brush Coupling
Flange
(see section
at page
.
• Unplug the Solution Hose that con-
nects the Solenoid Valve to the
Brush Motor.
• Loose the 4 blocking screws and re-
move the Brush Motor
(see fig.
.
• Proceed at reverse to refit the part.
Note:
Use the thread lock liquid on the
screw during the assembling.
4.2.4
Brush Deck Assembly -
Orbital
• Lower the Brush Deck and switch
Off the machine.
• Put the machine in safe conditions.
• Remove the Front carter by un-
screwing the fixing screws
(see fig.
• Remove the fixing screws to the
brush deck lifting arms.
• Disconnect the electrical connector
of the motor.
• Disconnect the water hose from the
solenoid valve.
4.2.4-19