General Sets
MENU
DEFAULT
VALUES
DESCRIPTION
General Sets:
Language
IT
IT-EN-FR-SP-
DE
Setup the language of the machine interface text.
General Sets:
Mod
BT
BT-BTO
Setup of the machine model BT=Disc BTO=Orbital
General Sets:
Battery
Gel60
Pb60-Gel60-
PPb-Pb80-
Gel80
Setup of the battery type.
General Sets:
Rst.Cnthr
No
Reset partial hourmeter (like on “working menu”).
General Sets:
Rst.Main Cnthr
No
Reset total hourmeter (key, brush, vacuum, traction).
General Setup:
Display Cnt
Traction
Key-Traction
Selection of the hourmeter type:
Key
connected to the Key -
Traction
connected to the traction
General Setup:
Display Tune
15
5-50
Display contrast
General Setup:
Display Brightness
0
0-10
Display brightness
General Sets:
Solution Management
No
No-HLR-HDC
Activation of optional devices.
General Sets:
Wand/Spray
No
No-Wand-
Spray
Activation of optional accessories.
Brushes Sets
Parameter
Default
Min
÷
Max
Description
Brushes Sets:
Max Mot current: [A]
40
20
÷
50
Maximum current from the main board to the brush motor.
Brushes Sets:
Nom Mot current: [A]
25
10
÷
40
Rated current; with T Nom manages the amperometric protection
(alarm + stop brush motor).
Brushes Sets:
Nom Mot time: [s]
30
1
÷
60
Rated timer; with I
Nom manages the amperometric protection
(alarm + stop brush motor).
Brushes Sets:
Switch Off Delay: [s]
0.0
0.0
÷
10.0
Delay of switching off of the brush motor when the safety lever is
released.
Brushes Sets:
Reset Delay: [s]
10
0
÷
100
Timing of reset amperometric protection (overcurrent)
Brushes Sets:
Switch On Delay: [s]
0.2
0.0
÷
5.0
Delay to switching on of the brush motor when the safety lever is
pressed. In the BTO version the default is 2.5.
Brushes Sets:
Speed Reduction: [V]
24
15
÷
24
Value of Voltage reduction of brush motor, during ECO mode. In the
BTO version the default is 17.
Brushes Sets:
Pressure 1: [A]
10
0
÷
40
First pressure level associated with an average current value ab-
sorbed by the brush motors.
Brushes Sets:
Pressure 2: [A]
20
0
÷
40
Second pressure level associated with an average current value ab-
sorbed by the brush motors.
Brushes Sets:
Pressure Range: [A]
2
0
÷
10
Current Range.
44
Summary of Contents for TRIDENT T20SC PRO
Page 1: ...SERVICE MANUAL TRIDENT T20SC PRO Version AB Date November 7 2018 Document Number 10077483...
Page 4: ...Part I Product Introduction 4...
Page 8: ...Part II Anomalies Resolution Guide 8...
Page 28: ...Part III Machine Description 28...