Technical Data
105/145
PC Cards cifX PCI, PCIe, Low Profile PCIe | Installation, Operation and Hardware Description
DOC120204UM36EN | Revision 36 | English | 2012-10 | Released | Public
© Hilscher, 2008-2012
10.1.14 CIFX 50E-CC
Item
CIFX 50E-CC
System Interface
(Bus Type)
PCI Express, One Lane Port, according to [bus spec 2, according Rev. 1.0a]
and [bus spec 3], (refer to section
Overview on the Pin Assignment at the Bus
,
page 95), transmission rate 2 GBit/s, 32-Bit width for the data access to the
Dual-Port Memory (DPM), or IO-DMA* (Direct Memory Access); *beginning
from Hardware Revision 3
Dual-Port Memory Size
64 KByte
Function
Communication interface with PCI and CC-Link interface
Communication
Determined by the loaded firmware
Protocols
CC-Link Slave
Processor
netX 100
LEDs
SYS, L RUN, L ERR; (refer also to chapter
LED Descriptions
, page 66).
Rotary Switch Slot Number
(Card ID)
To set the Slot Number (Card ID)
Configuration Software
netX Configuration Tool or SYCON.net
CC-Link Interface
Screw terminal connector, 5 pin; (RIACON Type 166);
Isolated RS-485 Interface; (refer also to chapter
CC-Link Interface
, page 90).
Supply Voltage
+3.3 V dc ±5/ Typ. 800 mA
Dimensions (L x W x D)
Beginning with hardware revision 3: 120 x 89,9 x 18,5 mm
Operating Temperature
0 °C ... +55 °C
Environment
The device must be used in a pollution degree 2 environment.
UL Certification
The device is UL 508 certified (UL-File No E221530).
Table 100: Technical Data CIFX 50E-CC
10.1.15 CIFX 50E-CP
Item
CIFX 50E-CP
System Interface
(Bus Type)
PCI Express, One Lane Port, according to [bus spec 2, according Rev. 1.0a]
and [bus spec 3], (refer to section
Overview on the Pin Assignment at the Bus
,
page 95), transmission rate 2 GBit/s, 32-Bit width for the data access to the
Dual-Port Memory (DPM), or IO-DMA* (Direct Memory Access); *beginning
from Hardware Revision 3
Dual-Port Memory Size
64 KByte
Function
Communication interface with PCI and CompoNet interface
Communication
Determined by the loaded firmware
Protocols
CompoNet Slave
Processor
netX 100
LEDs
SYS, MS, NS; (refer also to chapter
LED Descriptions
, page 66).
Rotary Switch Slot Number
(Card ID)
To set the Slot Number (Card ID)
Configuration Software
netX Configuration Tool or SYCON.net
CompoNet Interface
Open Jack connector, 4-pin
(according to CompoNet Specification [1]);
(refer also to chapter
CompoNet Interface
, page 90).
Supply Voltage
+3.3 V dc ±5/ Typ. 800 mA
Dimensions (L x W x D)
Beginning with hardware revision 3: 120 x 89,9 x 18,5 mm
Operating Temperature
0 °C ... +55 °C
Environment
The device must be used in a pollution degree 2 environment.
UL Certification
The device is UL 508 certified (UL-File No E221530).
Table 101: Technical Data CIFX 50E-CP